Owner's manual
Instructions for Removing the Local Register
1.  To remove the register cover and clamp ring, remove the seal screw that acts as a hinge pin. Remove the clamp ring by 
spreading it slightly apart at the open side to provide clearance so it can be lifted o the meter head.
2.  Slide out the register lock plate, located between the register base and the meter head at the entrance side of the 
rotor cage.
3.  Rotate the register 45 degrees in either direction to release it from the bayonet lock detents on the head assembly.
4.  Release the retaining ring surrounding the register extension tube inside the rotor cage. Using a Truarc right-angle 
pliers, expand the retaining ring and, at the same time, pull the register tube out of the head unit, removing the 
register assembly.
Figure 8: Register and Operating Head Assembly 
(2" and 3" Meters shown)
Industrial Turbo Meters, Sizes 2" through 6"
Page 14  November 2013










