Owner's manual
MAINTENANCE
Maintenance Equipment
With the exception of a special change gear mesh gage and a calibration test tank, the tools required are the usual 
compliment of standard hand tools used by plumbers and mechanics.
Truarc Right-Angle Pliers Truarc P/N 1549 (Badger Meter P/N 57321-001)
Change Gear Mesh Gage Badger Meter P/N 21747-000
Preventive Maintenance
Periodic Inspection
1.  Visually inspect the turbo meter and meter-mounted accessory. Repair or replace components as required based on the 
visual inspection.
2.  Verify that the meter operates at the proper ow rate and pressure. A loss in pressure, coupled with the resulting decrease 
in ow rate, may indicate the screen in the upstream pipeline is clogged with material and requires cleaning.
Cleaning
1.  Clean all dust, dirt, grease, moisture or other foreign material from the exterior of the meter and meter-
mounted accessory.
2.  If the piping arrangement of the facility includes a ushing system, shuto the liquid ow to the meter. Flush the interior 
of the meter with an appropriate cleaning uid to remove any buildup of deposits or corrosion on the internal portion of 
the meter.
Calibration Check and Adjustment
Accuracy of Badger turbo meters is tested at the factory with water. However, due to possible use of liquids that could vary 
in viscosity, it may be necessary to recalibrate a meter under operating conditions. The following instructions are to assist in 
performing a calibration adjustment.
Accuracy Test
1.  Place a test tank of known volume at output of meter.
2.  Operate the meter until the test tank is lled to a calibrated level. Run at the actual ow rate used in the operation.
3.  Record the quantity indicated on the meter accessory.
4.  Perform the following calculations to determine percent of accuracy of the meter-accessory combination:
Qty. Indicated on Accessory
X 100 = Meter Accuracy
Actual Quantity in Test Tank
Example 1:
95 Gallons
x 100 = 95% Accuracy
100 Gallons
In this example, the accessory is slow and must be speeded up by a change gear or electronic scaling correction.
Example 2:
104 Gallons
X 100 = 104% Accuracy
100 Gallons
In this example, the accessory is fast and must be slowed down.
Industrial Turbo Meters, Sizes 2" through 6"
Page 8  November 2013