User's Manual

Detailed Operation instructions:
A. Receiver & Transmitter Operation modes:
ON: Power is ON to attached devices
Dusk to Dawn (Sensor): Power will turn on at dusk and remain on until dawn
2H: Power will turn on at dusk and remain on for 2 hours
4H: Power will turn on at dusk and remain on for 4 hours
6H: Power will turn on at dusk and remain on for 6 hours
8H: Power will turn on at dusk and remain on for 8 hours
OFF: Power is OFF to attached devices
B. The keys operation on outlet receiver:
First push the “Program(Power)” button, the power(ON/OFF) indicator will be ON;
Secondly push the “Program(Power)” button, the Dusk Dawn(sensor) indicator will be ON;
Thirdly push the “Program(Power)” button, the 2H indicator will be ON;
Fourth push the “Program(Power)” button, the 4H indicator will be ON;
Fifth push the “Program(Power)” button, the 6H indicator will be ON;
Sixth push the “Program(Power)” button, the 8H indicator will be ON;
Seventh push the “Program(Power)” button, all the indicator will be OFF;
The function indicators will starts cycling mode when you push the “Program(Power)” button again.
C. Re-Programming/Self-Learning Operation between the outlets and transmitters:
The outlets are pre-programmed for immediate use, but maybe there are few units are not
pre-programmed or programmed incorrectly, or you want to change the pre-set configuration to meet your
needs. Please follow the steps below:
Resting an socket as per mentioned sections above firstly
Long Press and hold the programming button until indicator light on outlet starts to blink
Release the program button, press the “ON” or any button on the transmitter.
Programming /paring is successful when indicator light stops blinking.
D. Resetting an Outlet (Cancel programming):
To remove an outlet from all transmitter parings:
Unplug the device connected to the remote outlet
Remove the outlet from the power socket.
Press and hold the program button on outlet
Plug outlet back into power socket while continuing to hold program button for approximately 5 seconds
until the indicator begins to flash.
Program reset is successful when the indicator on outlet flashes several times and stops blinking
Notes:
1. In case of power failure, the outlets will go back to the off state and need to be reset to the desired
operating mode once power is restored.
2. In order to avoid the water into the outlets, The timer should be mounted in a vertical position with the
outlets facing downward and at least 2 feet above the ground level. If you can make sure the water does
not enter the outlets or use it indoor, please ignore the request.
3. Make sure the outlet is placed far from any artificial or reflected light source such as yard light, lawn lamp
or other lights to avoid interference due to the photocell (light sensor) factor used on the outlet.
4. For testing unit during daytime, covering the photocell firmly with black tape to simulate the darkness.