Nova-227 Outdoor LTE TDD eNodeB Installation Guide P/N: 1701000123 Version: 01 All rights reserved © Baicells Technologies Co., Ltd.
About This Document This document is a guidance of Nova-227 hardware installation for installation personnel, including the preparation of installation tools and supporting materials, the demands for installation environment, installation procedure, cable connection and power on. Accomplish the installation of the device according to this guide, the installation personnel can avoid potential damage to the device during the installation procedure, which makes sure the subsequent good running of the device.
1. Product Overview 1.1 Introduction Baicells Nova-227 is high performance outdoor micro eNodeB based on TDD LTE technology, which is developed by Baicells. The Nova-227 supports wired backhaul connections to backbone networks, and provides LTE access to user terminals, implemented voice and data service transmissions.
1.3 Appearance Table 1-1 Nova-227 Interface Description Interface Name ETH/PoE+ Description RJ-45 interface, used for data configuration or data backhaul, and PoE+ power supply. Table 1-2 Nova-227 Interface Indicators Identity Color PWR Green ACT Green RUN ALM Green Red Status Description Steady On Power On OFF No Power Supply Steady On The cell is activated. OFF The cell is not activated. Fast flash: 0.125s on,0.125s off The board is loading.
1.4 Technical Specification 1.4.
Item Description Modulation UL: QPSK, 16QAM, 64QAM DL: QPSK, 16QAM, 64QAM Voice Solution CSFB, VoLTE, eSRVCC Traffic Offload LIPA (Local IP Access) SIPTO (Selected IP Traffic Offload) SON Automatic setup ANR (Automatic Neighbor Relation) PCI confliction detection Spectrum Scanning Supported UL Interference Detection Supported RAN Sharing Supported Network Management Interface Support TR069 interface protocol MTBF ≥ 150000 hours MTTR ≤ 1 hour Support remote/local maintenance, based on SS
2. Installation Guide 2.1 Installation Preparation 2.1.1 Supporting Materials Item Description Ethernet cable Outdoor CAT6, Shorter than 100m (330 ft) Ground cable 16mm²yellow-green wire 2.1.2 Installation Environment 2.1.2.
2.2 Install on Pole 2.3 Install on Wall Note: According to the situation of the installation site, the angle of the eNodeB can be adjusted.
2.4 Connect Cable Before connect cables, unscrew the three screws on the cover of wiring cavity using M4 cross screwdriver and open the wiring cavity. After complete the connection, close the cover and fasten screws. Note: If the base station need to debug, connect the LAN interface to PC first and configure the IP address of the PC with 192.168.150.x. 2.
Appendix A Regulatory Compliance Only apply to the model pBS2120. FCC Compliance This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.