FLEXIBLE COUPLINGS, CONNECTOR AND CASTERS
For an appliance equipped with casters, the installation shall be made with a connector that complies
with the Standard for Connectors for Movable Gas Appliances, ANSI Z21.69 or Connectors for
Moveable Gas Appliances, CAN/CGA-6.16, and a quick disconnect device that complies with the
Standard for Quick Disconnect Devices for Use With Gas Fuel, ANSI Z21.41, or Quick Disconnect
Devices for Use With Gas Fuel, CANI-6.9.
If disconnection of the restraint is necessary, make sure to reconnect restraint after the appliance has
been returned to its originally installed position. Domestic gas or water connectors are not suitable.
Restraining device may be attached to the back frame / panel of the unit.
If the appliance is to be installed with casters, a flexible connector must be used and the same ANSI
standards apply. Locking front casters are provided to limit the movement of the appliance without
depending on the connector or associated piping. A suitable strain relief must be installed with a flexible
connector.
All connections must be sealed with a joint compound suitable for LP gas and all connections must be
tested with soap water solution before lighting pilots.
INITIAL PILOT LIGHTING
CAUTION: When lighting pilots and checking for leaks, do not stand with your
face close to the combustion chamber.
All
Bakers Pride appliances are adjusted and tested before leaving the factory, effectively matching them
to sea level conditions. Adjustments and calibrations to assure proper operation may be necessary on
installation to meet local conditions, low gas characteristics; correct possible problems caused by rough
handling or vibration during shipment and are to be performed only by qualified service personnel.
These adjustments are the responsibility of the customer and / or dealer and are not covered by our
warranty.
Check all gas connections for leaks with a soapy water solution before lighting any pilots.
DO NOT USE ANY FLAME TO CHECK FOR LEAKS
Before lighting any pilots, make sure that burner valves and thermostats are turned "OFF".
TOP BURNERS / RAISED GRIDDLE / BROILER
All top section burners are equipped with constant burning pilots. These are to be manually lighted
immediately after the gas is turned on and the system is checked for leaks. Burner pilots are provided
for each burner and can be rechecked for proper adjustment. All adjustments can be made with a screw
driver to the brass pilot valve accessible through the valve cover.
GRIDDLE
The pilot should be lighted immediately after the gas is turned on and the system is checked for leaks.
The pilot can be reached with a long match through the valve cover, or by lifting the plate upward and
accessing through the top. Adjustment of the pilot flame can be made with a screwdriver to the pilot
valve, accessible through the valve cover.
STANDARD OVEN
Pilot gas is tapped from the main burner manifold pipe, routed through tubing to a safety valve, and
then to a pilot burner. Gas flow is controlled by the safety valve.