Operation Manual
~ P.5 ~
7. WEATHER REPORT short cut button
Press to go straight into the weather report screen
8. [ ] button
Press this [ ] button to confirm
9. Screen ON-OFF button
Press to turn ON/OFF the display screen
C. OUTDOOR REMOTE THERMO-HYGRO SENSOR
1. LED indicator
Flashes when remote unit transmits a reading.
2,3. Temperature & Humidity display
LCD Displays for temperature and humidity readouts.
4. Channel number
Indicates the remote sensor is set to which channel and the user can find the corresponding
reading in the same channel in the linked receiving unit.
5. Battery compartment
Description of Buttons
The remote sensor has 3 function buttons inside the battery compartment (5).
6. [CH] button
After the battery installation, the LED blinks slowly every 1.5 seconds to indicate it is now under
channel setting mode and is set to channel 1 by default.
- If the user presses no key within 10 seconds, the unit will auto-exit the channel setting.
- If the user press [CH] button once during the channel setting, the LED will blink twice every 1.6
seconds to indicate the unit is set to channel 2.
- If the user press [CH] button again, the channel number will be advanced to channel 3 and the LED
will blink 3 times and so on.
The maximum channel number is “5” and the unit will be scrolled back to channel ‘1’ at the 5th press
of the [CH] button.
7. [°C/°F] Button
Press to toggle unit °C(Centigrade) or °F(Fahrenheit).
8. [RESET] Button
Press to hardware reset the unit to factory setting.
SETTING PROCEDURE TO LINK UP WITH the Frame UNIT
The remote sensor is designed for easy set up with no wire installation. The following steps are
required to be done in conjunction with the procedure descript in section 6 on “How to install remote
sensor”
1. Remove the bracket stand.
2. Unlock two latches in the bottom to release the semi-transparent jacket.
3. Slide down the battery door at the rear side.
4. Insert x2 AAA batteries according to polarity marking on the battery compartment.
5. The LED blinks slowly to indicate it is set to channel 1 and the user can change it to other channel
by pressing the CH key.
6. The temperature and humidity of the sensor will appear on the selected channel of the Frame unit
if it is linked up with the receiving unit successfully.
7. Close the battery door and use two latches in the bottom to lock it with the semi-transparent jacket.
Follow the same procedure (1 to 7) to register other remote sensors.
NOTE: For user purchasing more than one remote sensor, he must set the sensors to different channel
in the start up to avoid conflicts.
(ENG)










