User Manual 1
Table of Contents This manual assumes that the Poolux Control System has been installed and configured according to the Installation Manual. Important Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Important Water Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Important Electrical Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Important Notices SAFET Y PRECAUTIONS FCC STATEMENT The Warnings, Cautions, and Notes contained in this manual have the following significance. WARNING Maintenance or operating procedures and techniques that may result in personal injury, illness, or death if not carefully followed. CAUTION Maintenance or operating procedures and techniques that may result in damage to equipment and/or minor to moderate personal injury if not carefully followed.
Important Water Safety Instructions When installing and using this Control System, basic safety precautions should always be followed, including those listed below: READ & FOLLOW ALL INSTRUCTIONS The effects of hyperthermia include: Unawareness of impending hazard. Failure to perceive heat. Failure to recognize the need to exit the spa. Physical inability to exit the spa. Unconsciousness resulting in a danger of drowning.
Important Electrical Safety Instructions When installing and using this Control System, basic safety precautions should always be followed, including those listed below: READ & FOLLOW ALL INSTRUCTIONS 1. DANGER - Risk of electric shock. Before making any electrical connections, make certain that the Main Power breaker from the house breaker box has been turned off. 2. DANGER - Risk of Electric Shock. Do not permit any electric appliance, such as a light, telephone, radio, or television within 5' (1.
Basic Features of the Poolux Control System Your Poolux Control System is a multi-function pool/spa controller that can manage your complete system. It controls pumps, valves, lighting, heaters, chlorination, water features - whatever you can throw at it. And it is expandable! You have the technology in your hands to control your home resort all from one intuitive and intelligent wireless remote.
Poolux Wireless Panel Operation The Main Menu Screen options shown may be displayed in a different order on your control and will only appear if available on your system. BASIC PANEL FUNCTIONS Mode-Pool Arrow Left Arrow Up Pool Temp Pool Light 7 LEDs correspond to the 7 items on the left side of the display. They light to indicate operation or alert.
System Information Your system information (accessories and settings) can be viewed within a few screens, beginning with the Check Configuration menu (Menu 4 below). The basic equipment installed is shown: 1) Pool and/or Spa, 2) Expansion Boxes, and 3) other features (menus 5 and 6). The menus may appear different depending on your accessories.
Setting Day and Time Day of the week and AM/PM settings cannot be set separately. Day of the Week changes automatically according to the date input, and the AM/PM setting is changed with the hour setting.
Setting Filter Cycles Filter Cycle settings can be configured for use multiple times during a given day, as well as different programming for different days.
Setting Filter Cycles (cont’d) SETTING FILTER CYCLES 8b 8a Filter 1 Setup All Days Weekends Weekdays Sunday Monday Tuesday Filter 1 Setup Enable On1 On On On OOn On On 1 Wednesday Thursday Friday Saturday You will be given a choice of weekly or daily options to set up your filters for operation. Left Arrow to Exit.
Heater Settings Actual operation of various heating devices can be configured using this menu.
Setting Display Preferences Configuration of the wireless panel LCD is controlled using these menus. DISPLAY SET UP DISPLAY SET UP AT-A-GLANCE Main Menu Display Setup Backlight (min) Sleep Time (min) Assign Display2 Key Tone LCD Contrast 1 2 Pool Temp Mode Pool Main Menu Device Control Scenes / Timer Heater Chemistry Mode Setup Pool Light Air Temp Spa Light Filter Pump 10/09/06 Pool Set 80F Monday 12:42 PM Alert / Error Heater 3 3b Setup Setup Dolphinay and Time Displaylphin Version Info.
Renaming Devices Devices can be renamed to personal preference. For instance, Aux Device 1 can easily be renamed “Waterfall” and will then be shown that way on the control. Names are stored in the main control system.
Assigning Panel LEDs The LEDs to the left of the display can be reassigned to devices that are considered most important for that particular control panel. This is helpful for monitoring the on/off state of these devices without reading the display.
Creating Scenes Scenes are used to assign one or more devices to a preset timer. For example, a scene named “Evening” could be created that turns on a pool or spa light, and an auxiliary device such as a waterfall at the same time each evening.
A scene can also be manually turned on or off. If multiple devices are assigned to a scene, they will turn on or off simultaneously when the scene is turned on or off.
Vacation Mode Vacation Mode is used to disable scene timers when going on vacation. Each scene has an option in its setup called “Run in Vacation.” If set to Yes, the scene timers will continue to operate even though Vacation Mode is turned on or off.
Chemistry High and Low Limits for each chemistry reading has been set by the manufacturer. If the chemistry sensor reading is outside the present limits, an alert will flash on the Main Menu Screen. Default limits can be changed to your preference. CHEMISTRY CHEMISTRY SETTINGS AT-A-GLANCE Main Menu Chemistry Set High ORP Set Low ORP Set High pH Enable Set Low pH Set High TDS Ecomatic Disable Set Low TDS ORP threshold Enable Chlorine Gen.
Device Timeout A Device Timeout is the length of time a device will run if turned on manually and not turned off.
Check Alerts CHECK ALERTS CHECK ALERTS AT-A-GLANCE Main Menu Check Alerts 1 Pool Temp Mode Pool Pool Light Air Temp Spa Light Filter Pump Heater 10/09/06 Pool Set 80F Monday 12:42 PM Alert / Error (Display Screen) 2a 2b Main Menu Main Menu Device Control Scenes / Timer Heater Chemistry Mode Setup Check Alerts Setup Setup Pool (Main Menu) 3 ! Alerts & Errors If there is no error, this pop-up screen will appear.
Spa-Side Panel Set Up You may choose the equipment that you would like to associate with the first two Spa Panel buttons. The Temp and Mode buttons cannot be reassigned. Choose the piece of equipment from the Device List, then press Select when the piece of equipment you desire is highlighted as illustrated below.
Optional Dolphin Remote Set Up You must designate the equipment that you would like the Jet and the Aux buttons to operate from the Dolphin Remote. Choose the piece of equipment from the Device List, then press Select when the piece of equipment you desire is highlighted as illustrated below.
Poolux Wireless Panel Cradle Installation Option The Wireless Panel comes with a charging cradle that can be installed on a wall inside the home for a convenient display while charging. Installing the cradle is not necessary to charge the panel; it can be charged independently from the cradle with the charge cord. INSTALLING THE WIRELESS PANEL CRADLE The cradle must be mounted in a location where it receives a strong signal at all times.
Faults A Fault is an indication of a serious error that can affect the operation of the pool system. One of the following messages will blink on the lower right side of the Wireless Pool Control display when a fault occurs. FAULT MESSAGES AND MEANINGS AIR SENSOR FAULT The Air Temperature Sensor has failed or has been disconnected. WATER SENSOR FAULT The Water Temperature Sensor has failed or has been disconnected. SOLAR SENSOR FAULT The rooftop temperature sensor has failed or has been disconnected.
NOTES 26
NOTES 27
balboa instruments, inc. 1382 bell avenue tustin, ca 92780 www.balboa-instruments.