User manual
25
Faults 
A Fault is an indication of a serious error that can affect the operation of the pool system. One of the following 
messages will blink on the lower right side of the Wireless Pool Control display when a fault occurs.
AIR SENSOR FAULT     The Air Temperature Sensor has failed or has been disconnected.
WATER SENSOR FAULT    The Water Temperature Sensor has failed or has been disconnected.
SOLAR SENSOR FAULT    The rooftop temperature sensor has failed or has been disconnected.
pH SENSOR FAULT     The pH Sensor has failed or has been disconnected.
ORP SENSOR FAULT    The ORP Sensor has failed or has been disconnected.
TDS SENSOR FAULT    The Conductivity Sensor has failed or has been disconnected.
POC FAULT        The Pool Controller has lost communication with the POC board.
Alerts
An Alert will appear on the display during a change in System status, or when System levels are out of user-specified 
limits. One of the following messages will blink on the lower right side of the Wireless Poolux display when the System 
is bringing an Alert to your attention.
AIR SENSOR FREEZE    The air temperature has reached the preselected 34°F - 40°F set by the user. 
            The Filter Pump & devices configured to be freeze protected will turn on.
WATER SENSOR FREEZE   The water temperature has reached the preselected 34°F - 40°F set by the user. 
            The Filter Pump & devices configured to be freeze protected will turn on.
CHEMICAL FEEDER PURGE The Chemical Feeder is purging (15 seconds). The Filter Pump will not shut off 
            while this is occurring.
SOLAR PANEL DRAINING The Solar Valve is being held open to allow the solar panels to drain. The Filter Pump 
            will be held off while this occurs.
pH LOW          The pH of the water is below the user-specified low limit.
pH HIGH          The pH of the water is above the user-specified high limit.
ORP LOW        The ORP of the water is below the user-specified low limit.
ORP HIGH         The ORP of the water is above the user-specified high limit.
TDS LOW        The TDS of the water is below the user-specified low limit.
TDS HIGH         The TDS of the water is above the user-specified high limit.
DIRTY FILTER        The water pressure is above the dirty filter detection threshold. 
FAULT MESSAGES AND MEANINGS
ALERT MESSAGES AND MEANINGS