MOST MESSAGES AND ALERTS WILL APPEAR AT
THE BOTTOM OF THE NORMALLY USED SCREENS.
Several alerts and messages may be displayed in a sequence.
Some messages can be reset from the panel. Messages that
can be reset will appear with a right arrow at the end of the
message. This message can be selected by navigating to it at
pressing the Select button.
WATER TEMPERATURE IS UNKNOWN
---˚F ---˚C
After the pump has been running for 1 minute, the temperature
will be displayed.
POSSIBLE FREEZING CONDITION
A potential freeze condition has been detected, or the Aux Freeze
Switch has closed. All water devices are activated.
In some cases, pumps may turn on and off and the heater may
operate during Freeze Protection. This is an operational message,
not an error indication.
THE WATER IS TOO HOT – M029
The system has detected a spa water temp of 110°F (43.3°C) or
more, and spa functions are disabled. System will auto reset
when the spa water temp is below 108°F (42.2°C). Check for
extended pump operation or high ambient temp.
SENSORS ARE OUT OF SYNC – M015
The temperature sensors MAY be out of sync by 2°F or 3°F.
SENSORS ARE OUT OF SYNC -- CALL FOR SERVICE*
– M026
The temperature sensors ARE out of sync. The fault above has
been established for at least 1 hour.
SENSOR A FAULT, SENSOR B FAULT – SENSOR A:
M031, SENSOR B: M032
A temperature sensor or sensor circuit has failed. Call for Service
TP800, TP900 Sensor and System Related Messages (cont.)
COMMUNICATIONS ERROR
The control panel is not receiving communication from the
System.
TEST SOFTWARE INSTALLED
The Control System is operating with test software.
°F OR °C IS REPLACED BY °T
The Control System is in Test Mode.
PROGRAM MEMORY FAILURE* – M022
At Power-Up, the system has failed the Program Checksum Test.
This indicates a problem with the firmware (operation program)
and requires a service call.
THE SETTINGS HAVE BEEN RESET (PERSISTENT
MEMORY ERROR)* – M021
Contact your dealer or service organization if this message ap-
pears on more than one power-up.
THE CLOCK HAS FAILED* – M020
CONFIGURATION ERROR - SPA WILL NOT START UP
THE GFCI TEST FAILED (SYSTEM COULD NOT TEST
THE GFCI) – M036
(North America Only) May indicate an unsafe installation.
A PUMP MAY BE STUCK ON – M034
Water may be overheated. POWER DOWN THE SPA. DO NOT
ENTER THE WATER.
HOT FAULT M035
A Pump Appears to have been Stuck ON when spa was last
powered. POWER DOWN THE SPA. DO NOT ENTER THE
WATER.
Clean the filter `