Manual

35
On panels with “Warm and Cool buttons, to display the set
temperature, press “Warm” or Cool” once. To change the set
temperature, press a temperature button again before the
display stops flashing. Each press of “Warm” or Cool will
adjust the set temperature.
After three seconds, the display will stop flashing and begin
to display the current spa temperature.
JETS
Jets 1 500Z, 500DZ, 500SZ Series
Press “Jets 1” to turn pump 1 on or off, and to shift between
low and high speeds (if equipped). The low-speed will turn
off after 4 hours. High-speed will turn off after 15 minutes.
Low-speed may run automatically at times, during which it
cannot be deactivated from the panel, but high-speed may
be operated.
Jets 2/Jets 3/Blower (If equipped)
Press the corresponding button once to turn the device on or
off. The device will turn off after 15 minutes. Pump 2 may be
two-speed on some systems.
Some systems use this one button to control two devices.
The first button press will activate one device. Press again
to have both devices active. Press again to turn off the first
device only. Press one more time to turn both devices off.
Jets 300F (Software v. 41)
Press “Jets to turn the pump on or off, and to shift between
low and high speeds (if equipped). If left running, the pump
will turn off after a preset length of time, which on some
systems may be as long as 2 hours for low speed. Low speed
may run automatically at times, during which it cannot be
deactivated from the panel, but high speed may be operated.
The ozone generator (if installed) will activate anytime low
speed is running.
Jets 300, 300F (Software v. 38)
Press “Jets to turn the pump on or off, and to shift between
low and high speeds (if equipped). The low speed will turn
off after 4 hours. High speed will turn off after 15 minutes.
Low speed may run automatically at times, during which it
cannot be deactivated from the panel, but high speed may
be operated. The ozone generator (if installed) will activate
anytime low speed is running.
LIGHT
Press “Light” to operate the spa light. Turns off after 4 hours.
SETTING THE TIME OF DAY
When the spa is first powered up, the words SET TIME
will flash on the display. Press “Time,” then Mode/Prog,
then “Warm” or Cool. The time will begin changing in
one-minute increments. Press “Warm” or Cool to stop the
time from changing. Press “Time” to confirm.
MODE/PROG
Mode 500Z
Depending on system configuration, mode changing may
not be available and will be locked in Standard Mode.
Mode is changed by pressing Temp, then “Light”.
STANDARD Mode maintains set temperature.
will be
displayed momentarily when you switch into Standard
Mode.
ECONOMY Mode heats the spa to the set temperature
only during filter cycles. will display when water temp
is not current, and will alternate with water temp when
the pump is running.
SLEEP Mode heats the spa to within 20°F/10°C of the
set temperature only during filter cycles. will display
when water temp is not current, and will alternate with
water temp when the pump is running.
Mode 500SZ
Mode is changed by pressing Warm” or Cool, then
pressing “Mode.
STANDARD Mode maintains set temperature.
will be displayed momentarily when you switch into
Standard Mode.
ECONOMY Mode heats the spa to the set temperature
only during filter cycles. will display when water
temp is not current, and will alternate with water temp
when the pump is running.
SLEEP Mode heats the spa to within 20°F/10°C of the
set temperature only during filter cycles. will display
when water temp is not current, and will alternate with
water temp when the pump is running.