Diesel POW’R Products Generator DG3E and DG6E Installation & Operating Manual 5/05 MN2414
WARNING: CALIFORNIA PROPOSITION 65 WARNING: Engine exhaust from this product contains chemicals known to the state of California to cause cancer, birth defects and other reproductive harm. WARNING: CALIFORNIA PROPOSITION 65 WARNING: Battery posts, terminals and related accessories are known to the state of California to cause cancer, birth defects and other reproductive harm.
Table of Contents Section 1 Product Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Safety Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Responsibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ii Table of Contents MN2414
Section 1 Product Safety Information Safety Notice Be sure that you are completely familiar with the safe operation of this equipment. This equipment may be connected to other machines that have rotating parts or parts that are controlled by this equipment. Improper use can cause serious or fatal injury. Always disconnect all electrical loads before starting or stopping the generator. Installation and repair procedures require specialized skills with electrical generating equipment.
Precaution Statements Used In This Manual There are three classifications of precautionary statements used in this manual. The most critical is a WARNING statement, then the Caution statement and the least critical is the Note statement. The usage of each statement is as follows: WARNING: Indicates a potentially hazardous situation which, if not avoided, could result in injury or death. Caution: Indicates a potentially hazardous situation which, if not avoided, could result in damage to property.
Operation Warning Statements Continued WARNING: Be sure that you understand how to stop the engine quickly in case of an emergency situation. Become familiar with the controls and safety systems provided with this generator set. WARNING: Always wear safety glasses with side shields and hearing protection when working near the generator. WARNING: Improper operation may cause violent motion of connected equipment. Be certain that unexpected movement will not cause injury to personnel or damage to equipment.
Warning Statements Continued Burn WARNING: Parts of this generator are extremely hot during and after operation. To prevent severe burns, do not touch any part of the generator until you have first determined if the part is hot. Wear protective clothing and after use allow sufficient time for parts to cool before touching any part of the generator. WARNING: Do not touch the hot exhaust parts of the engine.
Warning Statements Continued Maintenance WARNING: Before servicing the generator set, be sure to disconnect the battery terminals to prevent accidental engine rotation or starting. WARNING: Before cleaning, inspecting, repairing, refueling or performing any maintenance to the generator set, always be sure the engine has stopped and that all rotating parts have also stopped. After stopping, certain components are still extremely hot so be careful not to get burned.
Caution Statements Caution: The brass connecting tab on some 120VAC duplex receptacles have been removed. Each receptacle is powered by a separate generator winding. When replacing a receptacle, inspect the brass tab that normally links both receptacles. If it is removed, be sure to remove the brass tab from the replacement receptacle before it is installed. Failure to remove the tab will cause a direct short to the generator windings and cause possible generator damage.
Section 2 General Information Thank you for purchasing your Baldor Generator Set. This manual contains information you need to safely and efficiently install and operate your generator set. During the preparation of this manual every effort was made to ensure the accuracy of its contents. This manual describes only very basic engine information. A separate owner’s manual for the engine is supplied with this unit for your use.
2-2 General Information MN2414
Section 3 Receiving & Installation Receiving & Inspection When you receive your generator, there are several things you should do immediately. 1. 2. 3. Observe the condition of the shipping container and report any damage immediately to the commercial carrier that delivered your system. Verify that the part number of the system you received is the same as the part number listed on your purchase order.
Physical Location The mounting location of the system is important. It should be installed in an area that is protected from direct harmful gases or liquids, dust, metallic particles, shock and vibration. It can only be installed in an outdoor location so the exhaust fumes are vented to the atmosphere. This system must never be installed inside an enclosed building, home, shop or garage etc. Several other factors should be carefully evaluated when selecting a location for installation: 1.
Electrical Connections Continued Table 3-1 Single Phase Power Receptacle Description Model DG3E DG6E Straight 120VAC (20Amp) 2− 5−20R GFCI 120VAC 4− 5−20R GFCI 120VAC Electrical Connection Information (Receptacle Provided at Panel) Twist Lock 120VAC Twist Lock 120/240VAC Twist Lock 120/240VAC (30Amp) (30Amp) (50Amp) 1− L5−30R 120VAC 1− L14−30R 120/240VAC 1− L5−30R 120VAC 1− L14−30R 120/240VAC Rated Watts/ (Full load Amps 120/240) 3300 / (25.0/12.5) 6000 / (50.0/25.
Frame Ground Connection Continued Figure 3-3 Frame Ground Connection Nut Washer Ground Wire Lug Washer Stud Earth Ground Engine Oil Frame Refer to the engine manual that was provided with your generator. Determine the correct type of engine oil and the amount specified by the engine manufacturer. Add the required amount of oil to bring the oil level to full. Caution: This generator must have a battery installed for operation. The battery is used during stating and during operation.
Battery Connections Continued Note: OHV units that have an electronic governor must have a battery installed before the Genset can be started (even with the pull starter). If no battery is present or the battery is discharged, the electronic governor will not operate and the generator set will not run. Procedure: The correct type battery must be purchased and installed in the battery compartment provided. 1. Remove the bag containing the battery box components. 2. Set the battery on the battery tray. 3.
Optional Wheel Kit PDG2 − 2 Wheel Dolly Kit; and PDG4 − 4 Wheel Dolly Kit An optional 2 or 4 wheel dolly kit is available for these portable generators. If you have purchased one of these kits, refer to MN2409 for the installation instructions. Recommended Engine Oil and Battery Type Series DG MODEL DG3E−15.70130 DG6E − 15.71520 3-6 Receiving & Installation SUMMER OIL *20W/50 *20W/50 WINTER OIL *5W/20 *5W/20 OIL CAPACITY 1.55 PTS 1.
Section 4 Operation Operator Control Panel Each operator panel is slightly different, depending on features of the generator you purchased. The Operator Control Panel of Figure 4-1 is shown because it has most of the available features. This will be used to explain how the controls operate. Figure 4-1 Operator Control Panel Start Switch (not shown) Push to engage the engine starter (if Run Switch is in the ON position). Run Switch (not shown) OFF − Turns off the engine (kill switch).
Pre−Start Checks Before the engine is started, several things must first be checked. 1. Place the generator set in an open, dry, well ventilated and reasonably level location. 2. If grounding is required for your application, check to make sure your unit is grounded properly (see Section3). 3. Check the engine’s oil level and add oil if necessary to bring it to the level recommended by the engine manufacturer. 4. Check the fuel level and add fuel to within 1/2 inch of the fill tube if necessary. 5.
Section 5 Troubleshooting and Maintenance Maintenance This manual contains only very minimal engine maintenance instructions. Refer to the engine manufacturer’s owner’s manual for specific engine maintenance instructions for your generator set. Any maintenance instructions or recommendations in the engine owner’s manual take precedence over any of the following general recommendations. General: 1. Inspect the fuel system for leaks. Replace all defective components immediately. 2.
Problems and Solutions Some of the more common problems are listed in Table 5-1. This information is intended to be a check or verification that simple causes can be located and fixed. It is not an exhaustive “how to” for all types of problems. Procedures that require in depth knowledge or skills (like flashing the field) should be referred to the Baldor Generator Service Department by calling (920) 236−4200. Table 5-1 Troubleshooting Guide Problem Engine will not start Possible Cause No fuel.
Appendix A DG Series Information in this Appendix applies to the following Baldor Generators: DG3E and DG6E. Caution: The brass connecting tab on some 120VAC duplex receptacles have been removed. Each receptacle is powered by a separate generator winding. When replacing a receptacle, inspect the brass tab that normally links both receptacles. If it is removed, be sure to remove the brass tab from the replacement receptacle before it is installed.
Replacement Parts Replacement parts assembly views for the Generator set are shown in Figure A-3 and A-4. Parts information is provided in Table A-1. Parts information for the engine is provided in the engine manual that was provided with your generator set. Please refer to the engine manual for replacement parts information. Figure A-3 Alternator Assembly 5 6 10 11 12 ON OFF 15 1 13 2 7 3 14 4 Figure A-4 Frame Assembly 23 22 21 21 HB7025A00 HB7025A02 OR HB7025A06 HB7025A07 RM1088A15 (.
Table A-1 Generator Set Parts List Continued Ref No. Not Shown Not Shown Not Shown Not Shown 13 14 15 16 Not Shown Not Shown Not Shown Not Shown Not Shown Not Shown Not Shown Not Shown Not Shown Not Shown Not Shown Not Shown Not Shown Not Shown Not Shown 20 20 20 21 21 21 21 21 22 23 Not Shown Not Shown Not Shown Not Shown Not Shown Not Shown Not Shown Not Shown Not Shown Not Shown Not Shown Not Shown Not Shown Not Shown Part No.
Figure A-5 DG3E Wiring Diagram A-4 Premier K Series MN2414
Figure A-6 DG3E Wiring Diagram with Low Oil & Remote Start MN2414 Premier K Series A-5
Figure A-7 DG6E Wiring Diagram A-6 Premier K Series MN2414
Baldor District Offices UNITED STATES ARIZONA PHOENIX 4211 S 43RD PLACE PHOENIX, AZ 85040 PHONE: 602−470−0407 FAX: 602−470−0464 CALIFORNIA LOS ANGELES 6480 FLOTILLA COMMERCE, CA 90040 PHONE: 323−724−6771 FAX: 323−721−5859 HAYWARD 21056 FORBES STREET HAYWARD, CA 94545 PHONE: 510−785−9900 FAX: 510−785−9910 COLORADO DENVER 2520 W BARBERRY PLACE DENVER, CO 80204 PHONE: 303−623−0127 FAX: 303−595−3772 FAX: 586−978−9969 MICHIGAN Continued GAND RAPIDS 668 3 MILE ROAD NW GRAND RAPIDS, MI 49504 PHONE: 616−785−1784 F
WARNING: CALIFORNIA PROPOSITION 65 WARNING: Engine exhaust from this product contains chemicals known to the state of California to cause cancer, birth defects and other reproductive harm. WARNING: CALIFORNIA PROPOSITION 65 WARNING: Battery posts, terminals and related accessories are known to the state of California to cause cancer, birth defects and other reproductive harm. BALDOR ELECTRIC COMPANY P.O. Box 2400 Ft.