User Guide
4-2 Parameter Index MN850
Applications Menu Continued 
Small PumpName
Start Pedestal %
Start Time
Current Limit Level
10
5
3.5
%
S
*FLC
Optimise Rate
Auto End Start
Soft Stop Smoothing
Auto 3MC
Low Voltage SoftStop
Auto Bypass
Auto Pedestal
Auto Stop
Auto Jog
Auto End Stop
Stop Pedestal %
Stop Time
10
30
%
S
Current Limit Time 25 S
Screw CompressorName
Start Pedestal %
Start Time
Current Limit Level
40
7
7.8125
%
S
*FLC
Optimise Rate
Auto End Start
Soft Stop Smoothing
Auto 3MC
Low Voltage SoftStop
Auto Bypass
Auto Pedestal
Auto Stop
Auto Jog
Auto End Stop
Stop Pedestal %
Stop Time
0
0
%
S
Current Limit Time 25 S
Large PumpName
Start Pedestal %
Start Time
Current Limit Level
10
7
3.5
%
S
*FLC
Optimise Rate
Auto End Start
Soft Stop Smoothing
Auto 3MC
Low Voltage SoftStop
Auto Bypass
Auto Pedestal
Auto Stop
Auto Jog
Auto End Stop
Stop Pedestal %
Stop Time
10
45
%
S
Current Limit Time 25 S
Rotary CompressorName
Start Pedestal %
Start Time
Current Limit Level
35
7
3.5
%
S
*FLC
Optimise Rate
Auto End Start
Soft Stop Smoothing
Auto 3MC
Low Voltage SoftStop
Auto Bypass
Auto Pedestal
Auto Stop
Auto Jog
Auto End Stop
Stop Pedestal %
Stop Time
0
0
%
S
Current Limit Time 25 S
Low Inertia FanName
Start Pedestal %
Start Time
Current Limit Level
30
15
3.5
%
S
*FLC
Optimise Rate
Auto End Start
Soft Stop Smoothing
Auto 3MC
Low Voltage SoftStop
Auto Bypass
Auto Pedestal
Auto Stop
Auto Jog
Auto End Stop
Stop Pedestal %
Stop Time
0
0
%
S
Current Limit Time 30 S
CrusherName
Start Pedestal %
Start Time
Current Limit Level
40
3
3.5
%
S
*FLC
Optimise Rate 2.8125
Auto End Start
Soft Stop Smoothing
Auto 3MC
Low Voltage SoftStop
Auto Bypass
Auto Pedestal
Auto Stop
Auto Jog
Auto End Stop
Stop Pedestal %
Stop Time
0
0
%
S
Current Limit Time 60 S
High Inertia FanName
Start Pedestal %
Start Time
Current Limit Level
40
3
2.8125
%
S
*FLC
Optimise Rate
Auto End Start
Soft Stop Smoothing
Auto 3MC
Low Voltage SoftStop
Auto Bypass
Auto Pedestal
Auto Stop
Auto Jog
Auto End Stop
Stop Pedestal %
Stop Time
0
0
%
S
Current Limit Time 60 S
GrinderName
Start Pedestal %
Start Time
Current Limit Level
40
3
2.8125
%
S
*FLC
Optimise Rate
Auto End Start
Soft Stop Smoothing
Auto 3MC
Low Voltage SoftStop
Auto Bypass
Auto Pedestal
Auto Stop
Auto Jog
Auto End Stop
Stop Pedestal %
Stop Time
0
0
%
S
Current Limit Time 60 S
ConveyorName
Start Pedestal %
Start Time
Current Limit Level
10
10
3.5
%
S
*FLC
Optimise Rate
Auto End Start
Soft Stop Smoothing
Auto 3MC
Low Voltage SoftStop
Auto Bypass
Auto Pedestal
Auto Stop
Auto Jog
Auto End Stop
Stop Pedestal %
Stop Time
0
7
%
S
Current Limit Time 30 S
High Torque StartName
Start Pedestal %
Start Time
Current Limit Level
60
3
4.375
%
S
*FLC
Optimise Rate
Auto End Start
Soft Stop Smoothing
Auto 3MC
Low Voltage SoftStop
Auto Bypass
Auto Pedestal
Auto Stop
Auto Jog
Auto End Stop
Stop Pedestal %
Stop Time
0
0
%
S
Current Limit Time 12 S
Reciprocating CompressorName
Start Pedestal %
Start Time
Current Limit Level
45
3
3.5
%
S
*FLC
Optimise Rate 15
Auto End Start
Soft Stop Smoothing
Auto 3MC
Low Voltage SoftStop
Auto Bypass
Auto Pedestal
Auto Stop
Auto Jog
Auto End Stop
Stop Pedestal %
Stop Time
0
0
%
S
Current Limit Time 25 S