Applications B-3MN850
   Read Only Parameter Values
Title P# Parameter Adjustable Range Factory User Setting
Parameters P74 2nd Last Trip 1–16 (Status Code) 0
P75 3rd Last Trip 1–16 (Status Code) 0
P76 4th Last Trip 1–16 (Status Code) 0
P77 5th Last Trip (Oldest trip) 1–16 (Status Code) 0
P78 Protection Mode 2 0–192 192 (Full + Optimize)
P79 Start Pedestal 2 10–60% 50 (% of line volts)
P80 Start Time 2 1–255 seconds 5 seconds
P81 Kick Pedestal 2 60–90% 75 (% of line volts)
P82 Kick Time 2 10–40 seconds 25 seconds
P83 Dwell 2 1–255 seconds 5 seconds
P84 Stop Pedestal 2 10–60 seconds 10 seconds
P85 Stop Time 2 0–255 seconds 0 seconds
P86 Auto Config 2 0–255 6 (Bit 00000110)
P87 Under Current 2 0–1 (x Ie) Amps 0.125 x Ie Amps
P88 Under Current Time 2 5–255 seconds 50 seconds
P89 Current Limit 2 0–8 (x Ie) Amps 4 x Ie Amps
P90 Current Limit Time 2 5–255 seconds 15 seconds
P91 Shearpin 2 1–5 (x Ie) Amps 3 x Ie Amps
P92 Shearpin Time 2 5–255 cycles 50 cycles
P93 Overload Level 2 0.5–2 (x Ie) Amps 1.09375 x Ie Amps
P94 Overload Delay 2 10–140 seconds 140 seconds
P95 User Flags 1 (for 2nd param set) 0–255 134 (Bit 10000110)
P96 User Flags 2 (for 2nd param set) 0–255 64 (Bit 01000000)
P97 Flag 1 I/P Source Address 0–125 0 (Parameter #)
P98 Flag 1 I/P Source Mask 0–128 0 (bit 00000000)
P99 Flag 1 O/P Destination Address 0–125 0 (Parameter #)
P100 Flag 1 O/P Destination Mask 0–255 0 (bit 00000000)
P101 Flag 2 I/P Source Address 0–125 0 (Parameter #)
P102 Flag 2 I/P Source Mask 0–20 0 (bit 00000000)
P103 Flag 2 O/P Destination Address 0–125 0 (Parameter #)
P104 Flag 2 O/P Destination Mask 0–11 0 (bit 00000000)
P105 Loop Input 0–125 41 (Parameter #)
P106 Loop Feedback 0–125 26 (Parameter #)
P107 Error Gain 1–255 37
P108 Error Divisor 1–255 7
P109 Max Slope 0–50 10
P110 Guard Gap 0–150 10