User Guide
9-1-2 
DC 
TERMINAL 
Check continuity between the DC terminals at the rear  of  the control panel using a circuit tester,  under 
the condition that the  DC terminals is mounted 
on the control panel. (See Fig. 
9-1.) 
w 
When continuity between the DC terminals is confirmed with a wire connected across the terminals, and 
is not confirmed 
if 
the wire 
is 
removed, the DC terminals are normal. (See Fig. 
9-1.) 
9-1-3 
CIRCUIT 
BREAKER 
Check continuity between the  two terminals 
at 
the rear side of  the circuit breaker  using a circuit tester 
while it is mounted 
on 
the control panel. 
If 
continuity 
is 
confirmed when  the breaker 
is 
ON, 
and no continuity is confirmed  when the breaker is 
OFF, 
the circuit breaker 
is 
normal. 
9-14 
VOLTMETER 
Check the voltmeter 
if 
it operates correctly by  apply- 
ing specified voltage. Voltmeters caunot be checked 
with a circuit tester because  its internal resistance 
is 
too large. 
9-2 STATOR 
Disengage connectors 
on 
the wires from stator  and 
check the resistance between wires with a 
“Dr. Robin” or a circuit tester referring to the follow- 
ing table. 
AC 
Voltmeter 
Fig. 
9-3 
I 
I 
Fig. 
9-4 
- 
27 
- 