User manual

Operation 5-9MN1851
Current Parameter
Nominal and peak current values are automatically entered for the motor type.
For manual tuning only, set the control current limit value to a percentage of the
continuous current rating. For example, if your control is rated for 5A continuous
current and you desire to limit the output current to 4A, enter 80%. If you wish to
use the full output power of the control, enter 100%. Click Download when
finished.
Figure 5-5 Current Parameter Screen
Velocity Parameter (Refer to HelpUnit Conversion from Linear to Rotary for more information)
Set the velocity parameters of the control:
Refer to Velocity Parameters (RPM m/s) at the end of this section.
1. Scale factor - ratio of the input voltage to output speed.
2. Minimum velocity
3. Time to maximum velocity
Click Download when finished.
Figure 5-6 Velocity Parameter Screen