Spec Sheet

Generator Specifications Preliminary
Standby Output 150
o
C
Rise kVA/kW
Single phase @ 240V ...................... 18/18
3 phase @ 208V .......................... 25/20
3 phase @ 240V .......................... 25/20
3 phase @ 480V .......................... 25/20
Prime Output 125
o
C
Rise kVA/kW
Single phase @ 240V ...................... 18/18
3 phase @ 208V .......................... 23/18
3 phase @ 240V .......................... 23/18
3 phase @ 480V .......................... 23/18
Amperage (Standby Rating) Amps
Single phase amperage @ 240/120V ....... 75/2X75
3 phase amperage @ 208V .................... 69
3 phase amperage @ 240V .................... 60
3 phase amperage @ 480V .................... 30
Voltage-3 phase adjustable
208/220/240/416/440/460/480
Voltage-Single phase adjustable 120/127/139/240/254/277
3 phase Power Factor ....................... 0.8
Voltage Regulation ....................... 1/2%
Frequency ............................ 60 Hertz
Total Harmonic Distortion .................. < 5%
Insulation ............................. Class H
Engine Specifications
Manufacturer .......................... John Deere
Model ................................ 4024TF281
Cylinders ...................................... 4
Induction system..................... Turbocharged
Displacement, L (cu. in.) .................. 2.4L (149)
EPA Emissions Level ..................Interim Tier 4
HP @ rated speed .............................. 48
RPM ....................................... 1800
Bore and stroke......................... 3.4” x 4.1”
Lubrication capacity (with filter) ............... 8.5 Qts
Battery recommendation (min. cold cranking amps) . 675
- Battery, battery rack and cable supplied
- Spin-on oil filter
- Thermostat controlled liquid cooling system
- 12V engine alternator
Receptacle Specifications
120 Volt 20 Amp Duplex GFCI .................... 2
120/240 Volt 50 Amp Twistlock (CS6369) ........... 2
Two wire remote start capability ................Yes
Fuel System Specifications
Fuel Consumption Standby Rating GPH
1/2 load .................................. 1.0
Full load .................................. 2.1
Approximate Run Time Hours
1/2 load ................................... 50
Full load ................................... 24
Fuel Capacity
Gallons ................................... 50
Fuel................................... Diesel
Weights and Dimensions
Weight without fuel ........................ 2530
Weight without fuel and without trailer ........ 2115
Dimensions with trailer
(L x W x H) .. 130” x 62” x 73”
Dimensions without trailer
(L x W x H) . 74” x 38” x 53”
Sound Level
Sound level dB(A) ........................... 67
7 meters, full load
Other Features
Start/Stop/Auto Switch, Alarm Horn, Voltage Adjust
Pot, Controller power Switch, Trailer Side Markers
and Running Lights.
© Baldor Electric Company Printed in U.S.A.
FM2411JT3 12/08 FARR 2000
Ratings: - Standby Ratings: Standby ratings are applicable for supplying emergency power for the duration of a utility power outage.
No overload capability for standby rating. Standby ratings in accordance with ISO 3046, BS55114, DIN 6271. Prime Power Rating:
Prime power is the maximum power available for continuous duty. A 10% overload capacity is available for 1 hour out of 12 hours of
operation. Manufacturer reserves the right to implement specifications or design changes without notice. WARNING: Do not connect
generator to any building’s electrical system unless a disconnect switch has been installed.