User's Manual
C827 REFERENCE MANUAL 
14 
4 
4.3  RS232 SERIAL CONNECTIONS 
The connections for the RS232 interface are RS232 TX (data from the C827), RS232 RX 
(data to the C827), and Ground or Signal GND it depends on selected Isolated/not isolated 
connection type. 
The signals and electrical loads from the RS232 TX and RS232 RX pins should conform to 
the electrical specifications of EIA Standard RS232. The maximum cable length specified 
under this standard is 15m. (50 feet). High quality shielded cable should be used for these 
connections. 
Table 4-1 gives the connections required to establish RS232 communications between the 
reader/writer and an RS232 host. 
Table 4-1: Serial/power connector pinouts 
C827 
Terminal 
Description RS232 
not isolated 
Description RS232 
isolated 
RS232 
Host, DE9 
RS232 Host, 
DB25 
1  Signal GND  Signal GND  N/C  N/C 
2  RS232 RX  RS232 RX  DE9 pin 3  DB25 pin 2 
3  VDC  VDC  N/C  N/C 
4  RS232 TX  RS232 TX  DE9 pin 2  DB25 pin 3 
5  Signal GND, GND  GND  DE9 pin 5  DB25 pin 7 