User's Manual

21
21
english
Function Description
Input buffer, configuration and explanation
Sub- Meaning Function Description
address
01Hex Error code (continued)
05
Hex Data carrier was removed from the active zone of the read/write
head while it was being written.
07
Hex AV bit is set but the command designator is missing or invalid.
or: Number of bytes is 00
Hex.
09
Hex Cable break to select read/write head, or head not connected.
0C
Hex The EEPROM cannot be read/programmed.
0D
Hex Communication with the read/write head.
0E
Hex The CRC of the read data does not coincide with the CRC of
the data carrier.
0F
Hex Contents of the 1st and 2nd bit header (1st and last bytes) of
the output buffers are not identical (2nd bit header must be
served).
20
Hex Adressing of the read/write job is outside the memory range of
the data carrier.
21
Hex Function invoked which is not possible for the data carrier
currently in front of the read/write head.
or: Data Data which was read from the data carrier.
(continued next )
Description of
Input Buffer
(continued)
Please note the
basic procedure on
12 and 30...36
and the examples
on pages
37...50.
L60_2-019_828132_1007-e.p65
22
english22
Function Description
Input buffer, configuration and explanation
Sub- Meaning Function Description
address
02Hex Data Data which was read from the data carrier.
... Data Data which was read from the data carrier.
Last byte
2nd Bit header The data are valid if the 1st and 2nd bit headers are in
agreement.
or: Data Data which was read from the data carrier.
Description of
Input Buffer
(continued)
Please note the
basic procedure on
12 and 30...36
and the examples
on pages
37...50.