Function Description
Parametering the BIS L-60_2 processor
Parameters,
Overview
There are 6 user parameter bytes stored on the Profibus master that can be used to activate
and deactivate various functions. Setting is done directly by linking a device to the Profibus
master. The parameter default settings are stored in the GSD file.
CRC_16 data check:
If this function is activated, the correctness of the read or written data is ensured by a
CRC_16 data check (see
8).
Dynamic operation on read/write head 1 or 2:
If dynamic operation is parametered, a read/write job can be sent even though there is no
Data carrier in the active zone of the head. As soon as a Data carrier passes by the head,
the command is immediately carried out.
"Auto-Read” for read/write head 1 or 2:
If this function is activated, the processor reads out the first (max. 31) bytes from the Data
carrier starting at a defined start address as soon as the tag enters the active zone of the
read/write head. The start address must first have been stored in the processor’s EEPROM
with the command ID 07
Hex.
2nd bit header at end of in- and output buffer:
The 2nd bit header (factory setting) prevents data from being accepted by the bus as long
as it is not fully updated.
Display state of the digital input in the bit header of the input buffer:
If this function is activated, the IN-bit displays the state of the digital input of the processor:
IN = 0 digital input low; IN = 1 digital input high
Please note the
basic procedure on
12 and 30...36
and the examples
on pages
37...50.
L60_2-019_828132_1007-e.p65
24
english24
Function Description
Parametering the BIS L-60_2 processor
Parameters,
Overview
(continued)
Reset BIS L-60_2 processor through the digital input:
If this function is activated, the processor is reset when the digital input is set to high.
– Selecting the data carrier type for processing:
Depending on the selection, either all or only specified data carriers may be processed.
Output data carrier model and serial number:
If this function is activated, at CT Present the data carrier model and serial number (UID =
unique ID) are output.
At data carrier model BIS L-1_ _-01 the serial number is 4 bytes. At all other data carrier
models the serial number is 8 bytes.
If this function is activated and dynamic mode is not set, no read data are output at
CT Present, but rather only the model and UID.
Please note the
basic procedure on
12 and 30...36
and the examples
on pages
37...50.