User's Manual

25
25
english
Parametering Bytes
User-Parameter Bytes
For parametering all 6 bytes must always be transferred in Hex. Only the bits men-
tioned may be changed. No guaranty will be given for the proper functioning of the
BIS L-60_2 if any of the other bits are changed.
The default values (factory setting) for the 6 bytes are:
1st byte 2nd byte 3rd byte 4th byte 5th byte 6th byte
H
EX 00 80 00 82 00 02
Binary 000
00000 10000000 00000000 10000010 00000000 00000010
bit 4 bit 1...8 bit 7 bit 1 bit 4 bit 1...8
bit 5 bit 5 bit 8 bit 2 bit 5
The bits which serve for parametering have the following functions:
1st byte, bit 5, Activate CRC_16 data checking
2nd byte, bit 5, Dynamic mode on read/write head 1
(for effects on read/write times, see
51)
2nd byte, bit 4, Activate Auto-Read function starting at specified address after CT present
for Head 1 (the number of bytes read depends on the selected buffer size
minus bit headers for Head 1)
3nd byte, bit 1...8 Select data-carrier model for processing:
00Hex: All data-carrier models
FE
Hex: Mifare: All Mifare data carriers supported by Balluff.
FF
Hex: ISO15693: All ISO15693 data carriers supported by Balluff.
Function Description
Parametering, Parametering Bytes
Bit state: 0 = no
1 = yes
These are used for
configuration:
Having the following
functions:
Please note the
basic procedure on
12 and 30...36
and the examples
on pages
37...50.
L60_2-019_828132_1007-e.p65
26
english26
4th byte, bit 8, Arrange a 2nd bit header at the end of the input and output buffers
If this function is selected, then the minimum size of both buffers is 4 words (8 bytes) each.
4th byte, bit 7, Display state of the digital input in the bit header of the input buffers:
0 = no
1 = yes Input is Low: "IN" in the bit header of the input buffers = 0.
Input is High: "IN" in the bit header of the input buffers = 1.
4th byte, bit 2, Reset the BIS L-60_2 processor through the digital input:
0 = no
1 = yes Input is Low: Do not reset.
Input is High: Reset.
4th byte, bit 1, Output data-carrier model and serial number at CT present:
0 = no At CT present the first data carrier data are output on Profibus.
1 = yes At CT present the data carrier model and serial number (UID = unique ID)
are output on Profibus. A distinction is made between type 01 with a
4-byte UID and type 03 with a 5-byte UID.
5th byte, bit 5 Dynamic mode on read/write head 2
(for effects on read/write times, see
51)
5th byte, bit 4 Activate Auto-Read function for Head 2 starting at specified address after
CT present (the number of bytes read depends on the selected buffer size
minus bit headers for Head 2)
Parametering Bytes
User-Parameter Bytes
(continued)
Function Description
Parametering, Parametering Bytes
Bit state: 0 = no
1 = yes
Please note the
basic procedure on
12 and 30...36
and the examples
on pages
37...50.