User's Manual

27
27
english
6th byte, bit 1...6 No. of bytes in input and output buffer which shall be used for
read/write head 1, see example on
16
The specification for the input and output buffer on the Master applies to both read/write
heads, i.e. this buffer must be divided for both heads. The specification is done in Hex format
and must be in a range between 02
Hex and 80Hex (128 dec.).
If only one read/write head (Head 1) will be used, you may enter the same value here as for the
total buffer size. An entry of less than 2 bytes results in an undefined state.
Please note the basic procedure on
12 and 30...36 and the examples on pages 37...50.
Parametering Bytes
User-Parameter Bytes
(continued)
Function Description
Parametering, Parametering Bytes
L60_2-019_828132_1007-e.p65
28
english28
Data-carrier models
BIS L-10_-01/L
CT present
Model BIS L-10_-01/L data carriers have a memory capacity of 192 bytes of user data.
These data can be read or programmed. These data carriers also have a unique, 4-byte
serial number, which is read-only.
The data carrier also contains additional memory ranges for configuration and protected
data. These areas cannot be processed using the BIS L-60_2 processor.
Model BIS L-10_-01/L data carriers are supplied with FF
Hex 37Hex configuration. Only data
carriers having this configuration are processed.
At CT Present the first user data are read from the data carrier and stored in the Profibus
input buffer (see
31). If the “Output data-carrier model and serial number at CT present”
function is enabled, model 01
Hex is output in Byte 1 of the input buffer and then the 4 bytes
representing the unique serial number.
The full command set of the BIS L-60_2 processor can be used with model BIS L-10_01/L
data carriers.
When using model BIS L-10_-01/L data carriers, the device parameterizing depends
mainly on the number of bytes to be read and programmed per head.
Please refer to 13ff and 23ff.
Functions
Device parameters
Data carrier
BIS L-10_-01/L