Examples for protocol sequence
Example No. 5
For configuring with
double bit header
and 8-byte buffer
size!
Write 16 bytes starting at data carrier address 20 (data carrier type BIS L-10 _-01/L):
Host:
1.) Process subaddresses of the output buffer in the
order shown:
BIS L-60_2 Identification System:
2.) Process subaddresses of the input buffer in the
order shown:
3.) Process subaddresses of the output buffer: 4.) Process subaddresses of the output buffer:
9.) Process subaddresses of the output buffer: 10.)Process subaddresses of the input buffer:
5.) Process subaddresses of the output buffer: 6.) Process subaddresses of the output buffer:
7.) Process subaddresses of the output buffer: 8.) Process subaddresses of the output buffer:
01
Hex
Command designator 02
Hex
02
Hex
/03
Hex
Start address 14
Hex
/ 00
Hex
04
Hex
/05
Hex
No. of bytes 10
Hex
/ 00
Hex
00
Hex
/07
Hex
Set AV-Bit
00
Hex
/07
Hex
Set AA-Bit, invert TO-Bit
01...06
Hex
Enter the first 6 data bytes
00
Hex
/07
Hex
Invert TI-Bit
01...06
Hex
Copy first 6 data bytes
Process subaddress of the input buffer:
00
Hex
/07
Hex
Invert TO-Bit
01...06
Hex
Enter the second 6 data bytes
00
Hex
/07
Hex
Invert TI-Bit
01...06
Hex
Copy second 6 data bytes
Process subaddress of the input buffer:
00
Hex
/07
Hex
Invert TO-Bit
01...04
Hex
Enter the remaining 4 data bytes
00
Hex
/07
Hex
Invert TI-Bit
01...04
Hex
Copy the remaining 4 data bytes
Process subaddress of the input buffer:
00
Hex
/07
Hex
Set AE-Bit
00
Hex
/07
Hex
Reset AV-Bit 00
Hex
/07
Hex
Reset AA-Bit and AE-Bit
L60_2-019_828132_1007-e.p65
44
english44
Example No. 6
Address assignment
for the Auto-Read
function
For configuring with
double bit header
and 8-byte buffer
size!
Programming start address 75:
01
Hex
Command designator 07
Hex
02
Hex
Start address Low Byte 4B
Hex
03
Hex
Start address High Byte 00
Hex
00
Hex
/07
Hex
Set AV-Bit
00
Hex
/07
Hex
Set AA-Bit and AE-Bit
To ensure correct data output, use command identifier 07Hex for each distributed buffer Head 1
and/or Head 2.
If the Auto-Read function is not activated, the processor runs in standard mode and sends
starting with data carrier address 0 until the buffer is filled.
☞
Host:
1.) Process subaddresses of the output buffer in the
order shown:
BIS L-60_2 Identification System:
2.) Process subaddresses of the input buffer:
3.) Process subaddresses of the output buffer:
4.) Process subaddresses of the input buffer:
00
Hex
/07
Hex
Reset AV-Bit
00
Hex
/07
Hex
Reset AA-Bit and AE-Bit
Function Description