User's Manual

51
51
english
Read/Write Times
Read times
All data are typical values. Deviations are possible depending on the application and combination
of read/write head and data carrier!
The data apply to static operation, no CRC_16 data checking.
Write times
Data carrier BIS L-2_ _
Recognize data carrier + read data carrier 270 ms
Data carrier BIS L-2_ _
Writing not possible
Data carrier with each 16 bytes/block BIS L-1_ _-01 BIS L-1_ _-02
Time for data carrier recognition/serial ID < 20 ms < 30 ms
Read bytes 0 to 15 < 20 ms < 30 ms
For each additional 16 bytes add another < 10 ms < 15 ms
Data carrier with each 16 bytes/block BIS L-1_ _-01 BIS L-1_ _-02
Time for data carrier recognition/serial ID < 20 ms < 30 ms
Write bytes 0 to 15 < 40 ms < 65 ms
For each additional 16 bytes add another < 30 ms < 45 ms
L60_2-019_828132_1007-e.p65
52
english52
Function displays
on BIS L-60_2
The BIS L-60_2 uses the three side-mounted LED's to indicate important conditions of the
identification system.
Status LED Meaning
Ready / red Supply voltage OK; no hardware error,
Bus active however, bus not active.
green Supply voltage / hardware OK,
bus active.
CT1 Present / green Data carrier read/write-ready at read/write head 1.
operating yellow Read/write command at read/write head 1 in
process.
yellow flashes Cable break to read/write head or not connected.
[f 2 Hz]
yellow flashes faster Communication with R/W Head 1 is faulty
[f 4 Hz] or R/W Head 1 is defective.
off No data carrier in read/write range of
read/write head 1.
CT2 Present / green Data carrier read/write-ready at read/write head 2.
operating yellow Read/write command at read/write head 2 in
process.
yellow flashes Cable break to read/write head or not connected.
[f 2 Hz]
yellow flashes faster Communication with R/W Head 2 is faulty
[f 4 Hz] or R/W Head 2 is defective.
off No data carrier in read/write range of
read/write head 2.
If all three LED's are synchronously flashing, it means a hardware error. Return the unit to the factory.
LED Display