User's Manual

53
53
english
BIS L-6002
Mounting the Processor
The processor is attached using 4 M4 screws.Mounting the
BIS L-6002
processor
X1 X2 X3
Head1Head2
12.5
12.8
16.8
150
90
4.3
71.6
45.5
~9.5
~19.6
18.5
21.5
82
BIS L-6002 dimensions
L60_2-019_828132_1007-e.p65
54
english54
BIS L-6002
Opening the Processor / Interface Information
X1 X2 X3
Head1Head2
BIS L-6002
interfaces
PROFIBUS
-DP
Output
PROFIBUS
-DP
Input
Connection locations
and names
Supply voltage
digital input
Function
ground FE
To set the PROFIBUS-DP address, activate or deactivate the internal termination resistor, or to
change the EEPROM, you must open up the BIS L-6002 processor.
Remove the 4 screws on the BIS L-6002 and lift off the cover. See the following
for addi-
tional information.
Connection for read/write head 2 Connection for read/write head 1
Opening the
BIS L-6002
processor
Be sure before
opening that the
unit is disconnected
from power.
Mounting of the cover
(4 screws),
max. permissible tightening
torque: 0.15 Nm