User's Manual

57
57
english
Wiring diagram for
BIS L-6002
processor
BIS L-6002
Interface Information / Wiring Diagrams
X1 X2 X3
Head1Head2
PROFIBUS-DP
Supply
voltage,
digital input
Function
ground FE
1
2
3
5
4
X1, supply voltage, digital input
X2, PROFIBUS-
input (male)
1
2
3
5
4
n.c. = do not
connect
X3, PROFIBUS-
output (female)
2
1
4
5
3
Pin Function
1VP
2A
3DGND
4B
5
n.c.
Pin Function
1+Vs
2–IN
3–Vs
4+IN
5
n.c.
Connection for Read/Write Head 2
The function-ground connector FE should be
connected to earth directly or through a RC
combination depending on the system (poten-
tial counterpoise).
When connecting the bus leads, make sure
that the shield has proper connection to con-
nector housing.
Connection for
Read/Write Head 1
Terminal location and
designation
L60_2-019_828132_1007-e.p65
58
english58
Changing the
EEPROM in the
BIS L-6002
processor
Location of the
EEPROM
BIS L-6002
Changing the EEPROM
To replace the EEPROM, open up the processor as described on 54.
Be sure before opening that the unit is discon-
nected from power.
To avoid damaging the EEPROM, please ob-
serve the requirements for handling electrostati-
cally sensitive components.
The EEPROM is replaced by unplugging and
plugging back into the socket.
X1 X2 X3
Head1Head2
1
on
2
4
3
on on
on
6
7
on
on
5
on
8
on
onon on
Head 1Head 2
S1
13246 578911121416 15 13 10
S2
1719 18