english
Dimensions,
Weight
Housing Plastic
Dimensions ca. 179 x 90 x 45,5 mm
Weight ca. 500 g
Ambient temperature 0 °C to + 60 °C
Enclosure rating IP 65 (when connected)
Integral connector X1 for V
S
, IN 5-pin (male)
Integral connector X2 for PROFIBUS-DP Input 5-pin (male)
Integral connector X3 for PROFIBUS-DP Output 5-pin (female)
Supply voltage V
S
DC 24 V ± 20 %
LPS Class 2
Ripple ≤ 10 %
Current draw ≤ 400 mA
PROFIBUS-DP slave Terminal block, electrically isolated
Digital Input (+IN, –IN) Optocoupler isolated
Control voltage active 4 V to 40 V
Control voltage inactive 1.5 V to –40 V
Input current at 24 V 11 mA
Delay time, typ. 5 ms
Read/Write Head 2 x connectors 8-pin (female)
for all read/writ heads BIS L-3_ _
with 8-pin connector (male)
Operating
Conditions
Connections
Enclosure Rating
Electrical
Connections
BIS L-6002
Technical Data
L60_2-019_828132_1007-e.p65
60
english60
BIS operating messages:
Ready / Bus active LED red / green
CT1 Present / operating LED green / yellow
CT2 Present / operating LED green / yellow
BIS L-6002