User's Manual
19
19
english
BIS L-400-035-001-_ _-S115
Installation
30
7.3
ø5.3
40
ø100
7.3
5.3 (3x)
60
46
120
6.5
40
Power TP
Clear zone
Set screw
Active surface
L
Data carriers of type BIS L-10_-05 may only be used with the CRC_16 setting or with a serial
number duplicated by a BIS L-20_-03 data carrier.
Characteristic data
by data carrier
Characteristic data
by data carrier
(installed in clear
zone)
at v = 0 (static condition)
Read
distance (mm)
 Center axis offset at a
distance of: (mm)
0-25 0-35 0-45 0-15
BIS L-200-03 /
L-100-05
0 - 30 ± 15
--
-
BIS L-201-03 /
L-101-05
0 - 40 - ± 20 - -
BIS L-202-03 /
L-102-05
0 - 55 - - ± 30 -
BIS L-203-03 /
L-103-05
0 - 20 - - - ± 10
Speeds (at standard setting data
comparison counter = 2):
at read
distance
[mm]
Speed [m/s]
BIS L-200-03 15 0.4
BIS L-201-03 20 0.45
BIS L-202-03 27.5 0.6
BIS L-203-03 10 0.28
at read
distance
[mm]
Speed [m/s]
BIS L-100-05 15 0.45
BIS L-101-05 20 0.5
BIS L-102-05 27.5 0.72
BIS L-103-05 10 0.36
Speeds (at "BIS L-10_-05" and "CRC
data check"):
L-400_835996_0803_E.p65
20
english20
BIS L-400-035-002-_ _-S115
Installation
Data carriers of type BIS L-10_-05 may only be used with the CRC_16 setting or with a serial
number duplicated by a BIS L-20_-03 data carrier.
Characteristic data
by data carrier
Characteristic data
by data carrier
(installed in clear
zone)
at v = 0 (static condition)
Read
distance (mm)
 Center axis offset at a
distance of: (mm)
0-10 0-15 0-20 0-25
BIS L-200-03 /
L-100-05
0 - 23 ± 12 ± 12 ± 8 -
BIS L-201-03 /
L-101-05
0 - 27 ± 15 ± 15 ± 15 ± 6
BIS L-203-03 /
L-103-05
0 -16 ± 8 ± 4 - -
Active surface
Clear zone
Cable length
50 cm
Set screw
Cable length max. 20 m
at read
distance
[mm]
Speed [m/s]
BIS  L-100-05 11.5 0.22
BIS  L-101-05 13.5 0.3
BIS L-103-05 8 0.18
at read
distance
[mm]
Speed [m/s]
BIS  L-200-03 11.5 0.18
BIS  L-201-03 13.5 0.22
BIS L-203-03 8 0.15
Speeds (at standard setting data
comparison counter = 2):
Speeds (at "BIS L-10_-05" and "CRC
data check"):