Data carriers of type BIS L-10_-05 may only be used with the CRC_16 setting or with a serial
number duplicated by a BIS L-20_-03 data carrier.
Characteristic data
by data carrier
Characteristic data
by data carrier
(installed in clear
zone)
at v = 0 (static condition)
Read
distance (mm)
 Center axis offset
at a distance of:
(mm)
0-5 0-8 0-11
BIS L-203-03 /
L-103-05
0 -11 ± 6± 4± 2
BIS L-400-035-003-_ _-S115
Installation
Active surface
Clear zone
Cable length
50 cm
Set screw
Cable length max. 20 m
at read
distance
[mm]
Speed [m/s]
BIS L-103-05 5.5 0.14
at read
distance
[mm]
Speed [m/s]
BIS L-203-03 5.5 0.11
Speeds (at standard setting data
comparison counter = 2):
Speeds (at "BIS L-10_-05" and "CRC
data check"):
L-400_835996_0803_E.p65
22
english22
Data carriers of type BIS L-10_-05 may only be used with the CRC_16 setting or with a serial
number duplicated by a BIS L-20_-03 data carrier.
Characteristic data
by data carrier
Characteristic data
by data carrier
(installed in clear
zone)
at v = 0 (static condition)
Read
distance (mm)
 Center axis offset at a
distance of: (mm)
0-10 0-15 0-20 0-25
BIS L-200-03 /
L-100-05
0 - 23 ± 12 ± 12 ± 8 -
BIS L-201-03 /
L-101-05
0 - 27 ± 15 ± 15 ± 15 ± 6
BIS L-203-03 /
L-103-05
0 -16 ± 8 ± 4 - -
BIS L-400-035-004-_ _-S115
Installation
Set screw
Active surface
Cable length 50 cm
Cable length max. 20 m
Clear zone 50
Clear zone 50
Clear zone 50
at read
distance
[mm]
Speed [m/s]
BIS  L-100-05 11.5 0.22
BIS  L-101-05 13.5 0.3
BIS L-103-05 8 0.18
at read
distance
[mm]
Speed [m/s]
BIS  L-200-03 11.5 0.18
BIS  L-201-03 13.5 0.22
BIS L-203-03 8 0.15
Speeds (at standard setting data
comparison counter = 2):
Speeds (at "BIS L-10_-05" and "CRC
data check"):