BIS L-400-035-001-_ _-S115
Reorienting and Rotating the Read Head
Reorienting the read
head
- Remove the two screws on the read head base
- Turn the read head module 180°
- Tighten both screws
- Unscrew the set screw
- Read head module can be rotated stepless (complete with read head base) to the
desired position (range: 270°)
- Tighten set screw
- Read head module is secured against over-rotation
Rotating the read
head
Read head modules are not interchangeable!
Active surface
positions
Read head
base
Screw
Active
surface
Set screw
BIS L-400 module
Mounting base
Read head
module
L-400_835996_0803_E.p65
24
english24
BIS L-400-035-00_-_ _-S115
Installation
Pin assignments
BIS L-400-...
RS232 = 00 RS422 = 02
Color code using cables
BKS-S116-PU / -S115-PU
1 OUT TP A (R+) yellow
2TxD Y (T+) gray
3RxD B (R-) pink
4NC NC red
5 RTS (TP) Z (T-) green
6-VS -VS blue
7+VS +VS brown