User's Manual

25
25
english
General data Housing Plastic (PBT)
Ambient temperature 0 °C to +60 °C
Enclosure rating IP 67 (only when assembled)
Supply voltage DC 24 V +10 % / –20 % (incl. ripple)
Current consumption 50 mA with no load
Output current per output max. 50 mA
Power LED green
Tag Present LED yellow
Overflow LED yellow flashing
(The "Tag Present" LED flashes rapidly if the data
from a data carrier were not completely read and a
new data carrier has arrived in the active zone.)
BIS L-405
Technical Data
Temperature range
Enclosure rating
Supply voltage
The CE Marking verifies that our products conform to the requirements of the
EU Directive
2004/108/EC (EMC Directive)
and the EMC Law. In our EMC Laboratory, which is accredited by the DATech for Testing
Electromagnetic Compatibility, we have verified that Balluff products meet the EMC re-
quirements of the following Generic Standards:
EN 61000-6-4 (Emission), EN 61000-6-2 (Noise Immunity).
LED function
indicator
BIS L-405-03_-00_-05-MU_834487_E_0709.p65
26
english26
Balluff Identification System
Series L
Hardware-Type
405 = Plastic housing
Software-Type
033 = 8 bits parallel
037 = 8 bits parallel with CRC_16 data check
Hardware version
001 = Coil Ø 34 mm
002 = discharged read head modules M18 (0.5 m cable)
003 = discharged read head modules M12 (0.5 m cable)
004 = discharged read head modules C-305 housing (0.5 m cable)
Interface
05 = parallel
Module
MU = Module unit
Used only together with mounting base BIS L-503-PU1-...
BIS L-405-03_-00_-05-MU
BIS L-405
Ordering Information
Part Numbers
Read head modules are not interchangeable!