8.1 Required data
Saving the
parameters
Setting the processor parameters
8
BIS L-409 IO-Link Device
Processor
The device-specific parameters for the identification system application are in addresses 10hex ...
12hex. The parameter data are described in greater detail in the following.
DPP SPDU Parameter Data
width
Value
range
Default value
Address Index Subindex
Identification data
07hex 0 8
Vendor ID 2 bytes
Read only
0378
hex
08hex 0 9
09hex 0 10
Device ID 3 Byte 060101hex0Ahex 0 11
0Bhex 0 12
Parameter data
10hex 1 1 CRC_16 check 1 byte 0/1 0
11hex 1 2 BIS L-10x-05 1 byte 0/1 0
12hex 1 3
Data comparison
counter
1 byte 1...10 2
The parameters can be accessed on the parameter data channel using Index, Subindex and
length (in bytes). With Subindex 0 all 16 bytes of the Index can be accessed; the length deter-
mines how many parameters are read or written. With a Subindex > 0 a particular element of the
Index is accessed, and the length specification is not used. Specification of these values
depends on the IO-Link Master and the controller.
There are parameters which can only be read, while others can be read and written (
see “Direct
Parameter Page” on page 3
0
).
Note
The values of the unused device-specific parameters 13
hex to 1Bhex must be set to
“0”.
The configured parameters are immediately valid as soon as they are set. However, if there is a
power loss the user-defined settings will be lost. The device is restarted with the factory settings,
and any other parameter setting needs to be made again.