User's Manual

8
3.1 Mechanical
connection
Getting Started
3
A
41
Fig. 1: BIS L-409-045-001-07-S4 with integrated read head, dimensions in mm
A Clear zone
Attach the processor using 4 M4 screws.
Note maximum tightening torque of 15 Ncm.
In addition to the processor with integrated read head, the following processors with remote read
head are available.
The processors with remote read head are also tightened using 4 M4 screws to a max. tighten
-
ing torque of 15 Ncm:
A
41
Fig. 2: Processor BIS L-409-045-002-07-S4, dimensions in mm
A Clear zone
BIS L-409 IO-Link Device
Processor