User Manual

CHAPTER 7: RFID COMMANDS
COBALT HF RFID CONTROLLERS OPERATOR’S MANUAL
P/N: 17-1320 REV 01 (03-06) PAGE 94 OF 116
Stopping Continuous Read - Response from Controller
PARAMETER FIELD MSB LSB
Overall Length of Response
(in words)
0x00 0x06
AA
in MSB
Command Echo
in LSB
0xAA
0x0D
00
in MSB
Node ID Echo
in LSB
0x00 0x01
Month
and
Day
timestamp
Month DOM
Hour
and
Minute
timestamp
Hour Minutes
Seconds
timestamp in MSB
00
in LSB
Seconds 0x00