User Manual

CHAPTER 7: RFID COMMANDS
COBALT HF RFID CONTROLLERS OPERATOR’S MANUAL
P/N: 17-1320 REV 01 (03-06) PAGE 96 OF 116
C OMMAND 35 (RESET C ONTROLLER)–CBX C OMMAND E XAMPLE
Command from Host
DESCRIPTION MSB LSB
Overall Length of Command
(in words)
0x00 0x06
AA
in MSB
Command ID
in LSB
0xAA
0x35
00
in MSB
Node ID
in LSB
0x00 0x01
Not Used:
(default: 0x00, 0x00)
0x00 0x00
Not Used:
(default: 0x00, 0x00)
0x00 0x00
Not Used:
(default: 0x00, 0x00)
0x00 0x00
Response from Controller
DESCRIPTION MSB LSB
Overall Length of Response
(in words)
0x00 0x06
AA
in MSB
Command Echo
in LSB
0xAA
0x35
Instance Counter
in MSB
Node Echo
in LSB
Instance Counter 0x01
Month
and
Day
timestamp
Month Day
Hour
and
Minute
timestamp
Hour Min
Seconds
timestamp in MSB
00
in LSB
Seconds 0x00