User Manual

CHAPTER 7: RFID COMMANDS
COBALT HF RFID CONTROLLERS OPERATOR’S MANUAL
P/N: 17-1320 REV 01 (03-06) PAGE 98 OF 116
Response from Controller
PARAMETER
FIELD
CONTENT DESCRIPTION CONTENT
SAMPLE
Header
2-byte Response Header (0x02, 0x02) 0x02, 0x02
Response Size
2-byte value for the total number of bytes in the
response packet, less Header, Command Size,
Checksum and Terminator bytes.
0x001B
Command Echo
0x38 0x38
RF Controller
Type
Controller Type default = 1 (0x01) 0x01
Major Release
Digit
The MAJOR release ASCII digit in the product
version number. Example product version
number:
0.0t.14
.
Major Release Digit in this example = 0
0x30
Minor Release
Digit
The MINOR release ASCII digit in the product
version number. Example product version
number:
0.0t.14
.
Minor Release Digit in this example = 0
0x30
Correction
Release Digit
The CORRECTION ASCII digit in the product
version number. Example product version
number:
0.0t.14.
Correction Release Digit in this example = t
0x74
Point Release
Digit
The POINT RELEASE digit in the product
version number. Example product version
number:
0.0t.14.
Point Release Digit in this example = 14
0x0E
Hardware
Version
Cobalt HF-xxx-01Hardware Version, default =
01 (0x01)
0x01
Block 0, 1, and 2
CRC
2-byte value for block 0, 1, and 2 CRC:
(example: 986E)
0x986E
Block 3, and 4
CRC
2-byte value for block 3, and 4 CRC: (example:
986E)
0x986E
RC632 ID
5-byte value for the RC632 ID:
(example: 30FFFF0F04)
0x30, 0xFF,
0xFF, 0x0F,
0x04
RC632 RFU
3-byte value for the RC632 RFU.
(example: 000000)
0x00, 0x00,
0x00
RC632 Serial
Number
4-byte value for the RC632 Serial Number.
(example: 05E19644)
0x05, 0xE1,
0x96, 0x44
RC632 Internal
Information
2-byte value for the RC632 internal.
(example: B669)
0xB669