CHAPTER 8: ERROR CODES
COBALT HF RFID CONTROLLERS OPERATOR’S MANUAL
P/N: 17-1320 REV 01 (03-06) PAGE 101 OF 116
CHAPTER 8:
ERROR CODES
If the Cobalt Controller encounters a fault during operation, the response that is
generated will include a 1-byte error code. Entering an invalid Start Address for a Read
Data command, for example, will generate Error Code 0x32 (Invalid Programming
Address).
8.1 ERROR C ODE T ABLE
ERROR
CODE
ERROR NAME DESCRIPTION
0x04
FILL TAG FAILED Fill Operation Failed
0x05
READ DATA FAILED Read Data Command Failed
0x06
WRITE DATA FAILED Write Data Command Failed
0x07
READ TAG ID FAILED Read Tag ID Command Failed
0x08
TAG SEARCH FAILED Tag Search Command Failed / No
Tag Found
0x21
INVALID SYNTAX Command Contained a Syntax
Error
0x23
INVALID TAG TYPE Invalid or Unsupported Tag Type
0x30
INTERNAL CONTROLLER
ERROR
Generic Internal Controller Error
0x31
INVALID CONTROLLER TYPE Invalid Controller Type (when
Setting Configuration)
0x32
INVALID PROGRAMMING
ADDRESS
Invalid Tag Address Specified in
the Command
0x34
INVALID VERSION Invalid Software Version (when
Setting Configuration)
0x35
INVALID RESET Invalid Hardware Reset
0x36
SET CONFIGURATION
FAILED
Set Configuration Command Failed
0x37
GET CONFIGURATION
FAILED
Get Configuration Command Failed
0x83
COMMAND INVALID
OPCODE
An invalid Command ID number
was specified in the command.
0x84
COMMAND INVALID
PARAMETER
A parameter specified in the
command was invalid.