User's Manual

CHAPTER 3:
CONTROLLER CONFIGURATION
COBALT HF RFID CONTROLLERS OPERATOR’S MANUAL
P/N: 17-1320 REV 01 (03-06) PAGE 46 OF 116
3.2.1 Restoring Factory Default Settings
Note: read all instructions carefully prior to performing any of the operations below.
To restore factory defaults:
1. Place the Configuration Tag in the antenna’s RF field.
2. Reset power to the Cobalt Controller or issue the reset command (Command
0x35).
3. Two seconds after power returns to the Cobalt HF, remove the Configuration Tag
from the antenna’s RF field.
Default settings will be restored and the controller’s configuration will be reset. After
successfully resetting the controller to factory defaults, the unit will be configured to the
following values:
x Command Protocol: ABx Fast – without Checksum (-232, -422 and -USB models)
x Tag Type Recognized: ISO 15693 (IǜCode SLi)
x Serial Communications: 9600, N, 8, 1, N (-232 and -422 models)
x Subnet Node ID: 00 (-485 model only)
x IP Address: 192.168.253.110 (-IND model only)