User's Manual

CHAPTER 4: LED STATUS
COBALT HF RFID CONTROLLERS OPERATOR’S MANUAL
P/N: 17-1320 REV 01 (03-06) PAGE 49 OF 116
CHAPTER 4:
LED STATUS
Cobalt HF RFID Controllers have eight LEDs located on the front panel. These LEDs
display RF and communications activity, diagnostic information and power and Node ID
status.
4.1 LED DESCRIPTIONS
RF LED, color is red. The RF LED will
light when RF power is being
transmitted.
COM LED, color is green. The COM
(communications) LED indicates that
data is being transmitted. Upon receiving
a command, the COM LED will begin flashing
ON and OFF. After the controller completes
the operation and generates a command
response, the COM LED flashing will halt.
NODE ID LEDs (x5), colors are yellow
(see table below).
PWR LED, color is green. The PWR
(power) LED will remain ON while power
is applied to the Cobalt HF Controller.
N
ODE ID LED INDICATOR D EFINITIONS
NODE ID LED DESCRIPTION
Node ID 1 RS232 enabled
Node ID 2 RS422 enabled
Node ID 4 USB enabled
Node ID 8 Default IP Address enabled:
196.169.253.110 (-IND model only)
Node ID 16 Custom IP Address enabled (-IND model only)
All 5 Node ID LEDs LEDs Display Node ID in binary format (-485 model only)
Table 4-1: Node ID LED Indicator Definitions