User Manual Part 1

Title
LRP2000 Long Range Passive Reader/Writer
19
Figure 3-11. Input From Sourcing Contact
Figure 3.11 shows the switch on the high side with the low side
grounded. As this is a "Dry" contact (the current is limited to 15 mA) a
high quality sealed switch should be used.
Figure 3-12. Input From Sinking Contact
3 + OUT B Positive
4 - OUT B Negative
5 + OUT C Positive
6 - OUT C Negative
7 + OUT D Positive
8 - OUT D Negative
9 GND Neutral
Table 3-4:
Output Connector Pinout
Terminal
number
Signal name Polarity