LRP2000 Long Range Passive Reader/Writer
23
4
Communications Interface
4.1 Configuring the Serial Interface
COM1
In normal use for reading and writing RFID tags, communications with
the LRP2000 will be accomplished via the main communications
interface, COM1. This communications interface can be accessed by
both point-to-point and addressed serial communications protocols.
For point-to-point serial communication, the LRP2000 supports
RS232 and RS422 as the standard protocols. For multiplexed
communications, Ethernet is available as an option. Both RS232 and
RS422 interfaces are optically isolated. The RS422 interface is
especially suited for long cable lengths, and for noisy environments.
NOTE:
NOTE: The delay between the characters sent to the
controller cannot be longer than 200 ms.
The options for each configuration parameter for the COM1 interface
follow:
The default configuration parameters for COM1 are:
Table 4-2:
Baud rate 9600 bps
Number of Data Bits 8
Number of Stop Bits 1
Parity None
Handshake None
Table 4-1:
Baud rate
1200, 2400, 4800, 9600,
19200, 38400 bps
Number of Data Bits 7, 8
Number of Stop Bits 1
Parity Even, Odd, None
Handshake None, Xon/Xoff