User Manual Part 1

Configuring the Menu
LRP2000 Long Range Passive Reader/Writer
39
Delay Between Identical Decodes (0-60)
The Delay Between Identical Decodes parameters can have a value
of 0 to 60 seconds. When the Delay Between Identical Decodes is set
to 0, the LRP2000 will continuously read AND transmit tag data to the
host. This can flood the buffers and cause communication errors and
data loss.
Raw Read Response
If you have selected ABx Fast or ABx ASCII, you have the option of
stripping the command protocol from the data and adding a terminator
to separate the data packets. You can choose a CR (0DH) or CR/LF
(0DH, 0AH) to terminate the data.
Set RF Communication
The LRP2000 should be configured with the default (0) Fast Mode.
*** Set RF Communication ***
RF Communication? [0] Fast Mode* [1] Standard Mode 0
Save Changes to EEPROM? [0] No [1] Yes
Restore Factory Defaults
It is often helpful during troubleshooting to restore the LRP2000 to
known default values. To do so, select 5 from the "[1] Set-up
Operating Parameters" menu .
*** Restore Factory Defaults ***
Restore Factory Default? [0] No [1] Yes
The restored defaults will be saved to the EEPROM. The
communication defaults can also be restored by placing the main
board DIP switch number 5 in the ON position and then restarting the
LRP2000. After you have saved any changes, you must re-initialize
the LRP2000 with switch 5 in the OFF position.
Return to Main Menu
When you have completed your configuration, entering 6 will return
you to the initial menu. Unsaved changes will be effective until the
LRP2000 is reset. Saved changes will be loaded automatically the
next time the LRP2000 is reset, or upon selection of "[4] Exit to
Operating Mode" from the main menu.