User Manual Part 1

RFID Interface
LRP2000 Long Range Passice Reader/Writer
47
The multi-tag commands in the ABx protocols include a parameter
which is not used with ISO15693-compliant tags. The Byte allocated
for this obsolete parameter has been left in the multi-tag command
packets. It is referred to as the "Anticollision Index" in documentation
for EMS products with firmware support for LRP-L series tags. This
series of tags does not comply with the ISO-15693 standard. The
Anticollision Index is ignored by the controller and may be set to any
value, but to maintain consistency in the case that this byte is used in
the future, it is recommended to set this Byte to 00H.
Start Continuous Read
This parameter, included only on command 83H, is a one-Byte
parameter which starts the Continuous Read if set to 01H, and stops
the Continuous Read if set to 00H. Both of the other Continuous Read
commands-- 0DH and 8DH rely on the Number of Bytes to be read to
start and stop the command. If the Number of Bytes is set to any valid
nonzero value, the Continuous read starts. If it is set to zero, the
Continuous Read stops. The use of this additional parameter on
command 83H allows for the Number of Bytes to be set to zero upon
initiation of the command, thereby interrogating the tags only for their
serial numbers.
6.3 Standard Abx Protocol
6.3 ABx Standard Protocol
The ABx standard is a binary protocol, word (2-byte) oriented, so
thesyntax table reports the Most Significant Byte (MSB) and the
LeastSignificant Byte (LSB). In the serial transmission, the MSB
istransmitted first.
Field
Number
of Bytes
Content
Header 1 AAH
Command 1 Command Code
Start
Address
2 one word gives the first Byte of tag memory
to be accessed
Number of
Bytes
2 One word gives the number of contiguous
bytes to be accessed. Not used on 07H,
08H, 14H, 15H, 16H