User Manual
Table Of Contents
- LRP75 Long Range Passive Reader/Writer
- Table of Contents
- Getting Started
- Mechanical Specifications
- Power and Electrical Interface
- Configuration Menu
- Standard RFID Interface
- 5.1 Introduction
- 5.2 Command Timeout Values
- 5.3 Address Blocks
- 5.4 ABx Error Codes
- 5.5 Command Descriptions
- 5.6 ABx Standard Commands
- 5.6.1 Command 4 (04 Hex): Tag Fill
- 5.6.2 Command 5 (05 Hex): Block Read
- 5.6.3 Command 6 (06 Hex): Block Write
- 5.6.4 Command 7 (07H): Read Tag Serial Number
- 5.6.5 Command 8 (08 Hex): Tag Search
- 5.6.6 Command D (0D Hex): Start/Stop Continuous Block Read
- 5.6.7 Command E (0EH) Read SN and Data
- 5.6.8 Command F (0FH) Start/Stop Continuous Read SN and Data
- 5.7 ABx Fast Commands
- 5.7.1 ABx Command Packet Structure
- 5.7.2 Command 4 (04 Hex): Tag Fill
- 5.7.3 Command 5 (05 Hex): Block Read
- 5.7.4 Command 6 (06 Hex): Block Write
- 5.7.5 Command 7 (07H): Read Tag Serial Number
- 5.7.6 Command 8 (08 Hex): Tag Search
- 5.7.7 Command D (0D Hex): Start/Stop Continuous Block Read
- 5.7.8 Command E (0EH) Read SN and Data
- 5.7.9 Command F (0FH) Start/Stop Continuous Read SN and Data
- Technical Specifications
- LRP75 Beta Connections
- Models and Accessories
- ASCII Chart
Configuration Menu
14 LRP75 Long Range Passive Reader/Writer
The Main Board Configuration menu displays the current main board
software version number together with the RFID firmware version.
******** LRP75/76 Standard Program V1.3E ********
RF module:4.01J
Serial Port COM1:RS232, 9600, N, 8, 1 No Handshake
Operating Mode:ABx Standard
Tag Type: Phillips I-CODE 1
[1] Set COM1 Parameters
[2] Set Operating Mode
[3] Set Tag Type
[4] Restore Factory Defaults
[5] Download New Program
[6] Download RFID Firmware
[7] Exit to Operating Mode
Enter Selection:
4.2.1 Set COM1 Parameters
The Set COM1 Parameters menu is given below.
*** Set COM1 Parameters **
Operating mode? [0] RS232 [1] RS422
Baud Rate? [0] 1200 [1] 2400 [2] 4800 [3] 9600 [4] 19200
Data size? [0] 7bit [1] 8bit
Parity? [0] None [1] Even [2] Odd
Handshake [0] None [1] Xon/Xoff
Save Changes to EEPROM? [0] No [1] Yes
Enter the number corresponding to the parameter you wish to enable.
4.2.2 Set Operating Mode
The Set Operating Mode menu is given below.
*** Set Operating Mode ***
Commands Protocol? [0] ABx Standard [1] ABx Fast
Checksum? [0] Disabled [1] Enabled
Power up performing Continuous Read?
[0] NO
[1] Continuous Block Read (0DH) active
[2] Continuous Read SN and Data (0FH) active
-> 1
Start Address (0 to 47) 0
Length (1 to 48) 48
Delay Between Duplicate Decodes (0 to 60) 1
Raw Read Response? [0] NO [1] CR terminate [2] CR/LF
terminate 2
Save Changes to EEPROM? [0] No [1] Yes