User Manual
Table Of Contents
- LRP75 Long Range Passive Reader/Writer
- Table of Contents
 - Getting Started
 - Mechanical Specifications
 - Power and Electrical Interface
 - Configuration Menu
 - Standard RFID Interface
- 5.1 Introduction
 - 5.2 Command Timeout Values
 - 5.3 Address Blocks
 - 5.4 ABx Error Codes
 - 5.5 Command Descriptions
 - 5.6 ABx Standard Commands
- 5.6.1 Command 4 (04 Hex): Tag Fill
 - 5.6.2 Command 5 (05 Hex): Block Read
 - 5.6.3 Command 6 (06 Hex): Block Write
 - 5.6.4 Command 7 (07H): Read Tag Serial Number
 - 5.6.5 Command 8 (08 Hex): Tag Search
 - 5.6.6 Command D (0D Hex): Start/Stop Continuous Block Read
 - 5.6.7 Command E (0EH) Read SN and Data
 - 5.6.8 Command F (0FH) Start/Stop Continuous Read SN and Data
 
 - 5.7 ABx Fast Commands
- 5.7.1 ABx Command Packet Structure
 - 5.7.2 Command 4 (04 Hex): Tag Fill
 - 5.7.3 Command 5 (05 Hex): Block Read
 - 5.7.4 Command 6 (06 Hex): Block Write
 - 5.7.5 Command 7 (07H): Read Tag Serial Number
 - 5.7.6 Command 8 (08 Hex): Tag Search
 - 5.7.7 Command D (0D Hex): Start/Stop Continuous Block Read
 - 5.7.8 Command E (0EH) Read SN and Data
 - 5.7.9 Command F (0FH) Start/Stop Continuous Read SN and Data
 
 
 - Technical Specifications
 - LRP75 Beta Connections
 - Models and Accessories
 - ASCII Chart
 
 
Standard RFID Interface
24 LRP75 Long Range Passive Reader/Writer
5.6.3 Command 6 (06 Hex): Block Write
DESCRIPTION
Write a block of data to an RFID tag.
DISCUSSION
The RF Port Block Write command is used to write segments of data 
to contiguous areas of tag memory. It is capable of transferring up to 
48 bytes of data. The timeout value is given in 1 msec increments and 
can have a value of 1EH to FFFEH. A timeout of 0 will return a syntax 
error.
The data to be written to the tag is contained in the LSB of the register, 
and the MSB is always 00H.
Field Description
Header AAH
Command Command number in hex
Start Address The tag address where the write will start
Write Length The number of tag addresses to be written
Timeout Timeout value given in 1 ms units (1EH - FFFEH)
Write Data The data to be written
Message 
Te r mi n at o r