User Manual
Table Of Contents
- LRP75 Long Range Passive Reader/Writer
- Table of Contents
 - Getting Started
 - Mechanical Specifications
 - Power and Electrical Interface
 - Configuration Menu
 - Standard RFID Interface
- 5.1 Introduction
 - 5.2 Command Timeout Values
 - 5.3 Address Blocks
 - 5.4 ABx Error Codes
 - 5.5 Command Descriptions
 - 5.6 ABx Standard Commands
- 5.6.1 Command 4 (04 Hex): Tag Fill
 - 5.6.2 Command 5 (05 Hex): Block Read
 - 5.6.3 Command 6 (06 Hex): Block Write
 - 5.6.4 Command 7 (07H): Read Tag Serial Number
 - 5.6.5 Command 8 (08 Hex): Tag Search
 - 5.6.6 Command D (0D Hex): Start/Stop Continuous Block Read
 - 5.6.7 Command E (0EH) Read SN and Data
 - 5.6.8 Command F (0FH) Start/Stop Continuous Read SN and Data
 
 - 5.7 ABx Fast Commands
- 5.7.1 ABx Command Packet Structure
 - 5.7.2 Command 4 (04 Hex): Tag Fill
 - 5.7.3 Command 5 (05 Hex): Block Read
 - 5.7.4 Command 6 (06 Hex): Block Write
 - 5.7.5 Command 7 (07H): Read Tag Serial Number
 - 5.7.6 Command 8 (08 Hex): Tag Search
 - 5.7.7 Command D (0D Hex): Start/Stop Continuous Block Read
 - 5.7.8 Command E (0EH) Read SN and Data
 - 5.7.9 Command F (0FH) Start/Stop Continuous Read SN and Data
 
 
 - Technical Specifications
 - LRP75 Beta Connections
 - Models and Accessories
 - ASCII Chart
 
 
Standard RFID Interface
LRP75 Long Range Passive Reader/Writer 25
EXAMPLE
Writes 4 bytes of data to the tag starting at address 0001H. A timeout 
of 2 seconds (07D0H = 2000 x 1 msec increments) is set for the 
completion of the Block Write.
5.6.4 Command 7 (07H): Read Tag Serial Number
DESCRIPTION
This command retrieves the 8-byte tag serial number. 
DISCUSSION
Each LRP tag has a unique serial number. This number can not be 
changed and is not part of the 48 available data bytes. The tag serial 
number will be returned in the LSB only with the MSB as 00H. The 
timeout value is given in 1 msec increments and can have a value of 
1EH to FFFEH.
Command from the Host Response from the LRP75
MSB LSB Remarks MSB LSB Remarks
AAH 06H Perform Command 6 AAH 06H Command Echo
00H 01H Start Address = 0001H FFH FFH Message Terminator
00H 04H Write Length= 4 bytes 
(0004H)
07H D0H Timeout value
00H 41H Write Data 1 = 41H
00H 46H Write Data 2 = 46H
00H 49H Write Data 3 = 49H
00H 44H Write Data 4 = 44H
FFH FFH Message Terminator
Field Description
Header AAH
Command Command number in hex
Timeout Timeout value given in 1 ms units (1EH - FFFEH)
Message 
Terminator
FFFFH