User Manual
Table Of Contents
- LRP75 Long Range Passive Reader/Writer
- Table of Contents
 - Getting Started
 - Mechanical Specifications
 - Power and Electrical Interface
 - Configuration Menu
 - Standard RFID Interface
- 5.1 Introduction
 - 5.2 Command Timeout Values
 - 5.3 Address Blocks
 - 5.4 ABx Error Codes
 - 5.5 Command Descriptions
 - 5.6 ABx Standard Commands
- 5.6.1 Command 4 (04 Hex): Tag Fill
 - 5.6.2 Command 5 (05 Hex): Block Read
 - 5.6.3 Command 6 (06 Hex): Block Write
 - 5.6.4 Command 7 (07H): Read Tag Serial Number
 - 5.6.5 Command 8 (08 Hex): Tag Search
 - 5.6.6 Command D (0D Hex): Start/Stop Continuous Block Read
 - 5.6.7 Command E (0EH) Read SN and Data
 - 5.6.8 Command F (0FH) Start/Stop Continuous Read SN and Data
 
 - 5.7 ABx Fast Commands
- 5.7.1 ABx Command Packet Structure
 - 5.7.2 Command 4 (04 Hex): Tag Fill
 - 5.7.3 Command 5 (05 Hex): Block Read
 - 5.7.4 Command 6 (06 Hex): Block Write
 - 5.7.5 Command 7 (07H): Read Tag Serial Number
 - 5.7.6 Command 8 (08 Hex): Tag Search
 - 5.7.7 Command D (0D Hex): Start/Stop Continuous Block Read
 - 5.7.8 Command E (0EH) Read SN and Data
 - 5.7.9 Command F (0FH) Start/Stop Continuous Read SN and Data
 
 
 - Technical Specifications
 - LRP75 Beta Connections
 - Models and Accessories
 - ASCII Chart
 
 
Standard RFID Interface
28 LRP75 Long Range Passive Reader/Writer
NOTE:Other commands will NOT be performed when the LRP75 is 
performing continuous read.
EXAMPLE
The following example reads 8 bytes of data from a tag at address 
05H, with a delay between identical reads of 2. After a tag is read, it 
must remain out of the RF field for at least 2 seconds before it will be 
read again. The LRP75 will send a response confirming its in 
Continuous Block Read mode.
Field Description
Header AAH
Command Command number in hex
Start Address The tag address where the read will start
Read Length  The number of tag addresses to be read. A 0 length 
stops continuous mode.
Delay Between 
Identical Reads
Time period that the tag must be out of reading 
range before the LRP75 will send the same data to 
the host.
Message 
Te r mi n at o r
FFFFH
Command from the Host Response from the LRP75
MSB LSB Remarks MSB LSB Remarks
AAH 0DH Perform Command D AAH 0DH Command Echo
00H 05H Start Address FFH FFH Message Terminator
00H 08H Read Length
00H 02H Delay Between Identical 
Reads