User Manual
Table Of Contents
- LRP75 Long Range Passive Reader/Writer
- Table of Contents
 - Getting Started
 - Mechanical Specifications
 - Power and Electrical Interface
 - Configuration Menu
 - Standard RFID Interface
- 5.1 Introduction
 - 5.2 Command Timeout Values
 - 5.3 Address Blocks
 - 5.4 ABx Error Codes
 - 5.5 Command Descriptions
 - 5.6 ABx Standard Commands
- 5.6.1 Command 4 (04 Hex): Tag Fill
 - 5.6.2 Command 5 (05 Hex): Block Read
 - 5.6.3 Command 6 (06 Hex): Block Write
 - 5.6.4 Command 7 (07H): Read Tag Serial Number
 - 5.6.5 Command 8 (08 Hex): Tag Search
 - 5.6.6 Command D (0D Hex): Start/Stop Continuous Block Read
 - 5.6.7 Command E (0EH) Read SN and Data
 - 5.6.8 Command F (0FH) Start/Stop Continuous Read SN and Data
 
 - 5.7 ABx Fast Commands
- 5.7.1 ABx Command Packet Structure
 - 5.7.2 Command 4 (04 Hex): Tag Fill
 - 5.7.3 Command 5 (05 Hex): Block Read
 - 5.7.4 Command 6 (06 Hex): Block Write
 - 5.7.5 Command 7 (07H): Read Tag Serial Number
 - 5.7.6 Command 8 (08 Hex): Tag Search
 - 5.7.7 Command D (0D Hex): Start/Stop Continuous Block Read
 - 5.7.8 Command E (0EH) Read SN and Data
 - 5.7.9 Command F (0FH) Start/Stop Continuous Read SN and Data
 
 
 - Technical Specifications
 - LRP75 Beta Connections
 - Models and Accessories
 - ASCII Chart
 
 
Standard RFID Interface
LRP75 Long Range Passive Reader/Writer 31
5.6.8 Command F (0FH) Start/Stop Continuous Read 
SN and Data
DESCRIPTION
When in Continuous Block Read SN and Data mode, the LRP75 
sends Read SN and Data commands continuously to any tag in range 
of the antenna. The value in the Start/Stop field controls the command 
(start/stop). 
DISCUSSION
When a tag enters the field of the antenna, the LRP75 reads the SN 
and data, and then passes them to the host. The LRP75 continues to 
read the tag, but will not send the same data to the host until the tag 
has been out of the antenna’s range for a specified time period. This 
period is called the Delay Between Identical Reads. It prevents 
redundant data transmission when the LRP75 is in Continuous Read 
SN and Data mode. The Delay Between Identical Reads can have an 
integral value in seconds between 0 and 60. A value of 0 makes the 
LRP75 continuously read any tag in the RF field and send the data to 
the host.
The Start/Stop Continuous Read SN and Data command has a field to 
start and stop continuous reading. To stop Continuous Read SN and 
Data, issue the command with zero (0) in the start/stop byte. 
If the LRP75 receives any other command from the host while in 
continuous mode, an error (0FH) will be sent to the host. 
NOTE:Other commands will NOT be performed when the LRP75 is in 
continuous mode. 
Field Description
Header AAH
Command Command number in hex
Start Address The tag address where the read will start
Read Length  The number of tag addresses to be read
Delay Between 
Identical Reads
Time period that the tag must be out of reading 
range before the LRP75 will send the same data to 
the host.
Start/Stop  01H starts continuous mode and 00H stops it.
Message 
Terminator
FFFFH