User Manual

Table Of Contents
Standard RFID Interface
42 LRP75 Long Range Passive Reader/Writer
5.7.5 Command 7 (07H): Read Tag Serial Number
DESCRIPTION
This command retrieves the 8-byte tag serial number.
DISCUSSION
Each LRP tag has an unique serial number. This number can not be
changed and is not part of the 48 available data bytes. The tag serial
number will be return in the LSB only with the MSB as 00H. The
timeout value is given in 1 msec increments and can have a value of
1EH to FFFEH.
Field Description
Header <STX><STX>
Command Size Packet length in bytes, excluding the header,
command size, checksum and terminator bytes.
Command 07H
Timeout 2-byte timeout value given in 1 ms units (1EH -
FFFEH)
Checksum optional checksum
Message
Te r mi n at o r
FFFFH