User Manual

Table Of Contents
Standard RFID Interface
44 LRP75 Long Range Passive Reader/Writer
5.7.6 Command 8 (08 Hex): Tag Search
DESCRIPTION
Check to see if there is an RFID tag in the LRP75 field.
DISCUSSION
This command will activate the reader/write to "look" for a tag in the
RF field. If the LRP75 finds a tag it will return a command echo to the
host. The timeout value is given in 1 msec increments and can have a
value of 1EH to FFFEH. If no tag is present it will return an error
message.
Field Description
Header <STX><STX>
Command Size Packet length in bytes, excluding the header,
command size, checksum and terminator bytes.
Command 08H
Timeout 2-byte timeout value given in 1 ms units (1EH -
FFFEH)
Checksum optional checksum
Message
Te r mi n at o r
FFFFH