14 LRP76 Long Range Passive Reader/Writer
4.2 Configuration Menu
The Configuration Menu will display the current state of the operating
parameters. To change a parameter, enter the decimal number shown
in the menu for the option you want. An invalid entry will return you to
the Main Menu.
The Main Board Configuration menu displays the current main board
software version number together with the RFID firmware version.
******** LRP75/76 Standard Program V1.3E ********
RF module:4.01J
Serial Port COM1:RS232, 9600, N, 8, 1 No Handshake
Operating Mode:ABx Standard
Tag Type: Phillips I-CODE 1
[1] Set COM1 Parameters
[2] Set Operating Mode
[3] Set Tag Type
[4] Restore Factory Defaults
[5] Download New Program
[6] Download RFID Firmware
[7] Exit to Operating Mode
Enter Selection:
4.2.1 Set COM1 Parameters
The Set COM1 Parameters menu is given below.
*** Set COM1 Parameters **
Operating mode? [0] RS232 [1] RS422
Baud Rate? [0] 1200 [1] 2400 [2] 4800 [3] 9600 [4] 19200
Data size? [0] 7bit [1] 8bit
Parity? [0] None [1] Even [2] Odd
Handshake [0] None [1] Xon/Xoff
Save Changes to EEPROM? [0] No [1] Yes
Enter the number corresponding to the parameter you wish to enable.
4.2.2 Set Operating Mode
The Set Operating Mode menu is given below.
*** Set Operating Mode ***
Commands Protocol? [0] ABx Standard [1] ABx Fast
Checksum? [0] Disabled [1] Enabled
Power up performing Continuous Read?
[0] NO
[1] Continuous Block Read (0DH) active
[2] Continuous Read SN and Data (0FH) active
-> 1
Start Address (0 to 47)
Length (1 to 48)
Delay Between Duplicate Decodes (0 to 60)
Raw Read Response? [0] NO [1] CR terminate [2] CR/LF terminate
Save Changes to EEPROM? [0] No [1] Yes